Compax3 device description

Power supply plug X1 for 400 VAC devices

3.1.3.
Power supply plug X1 for 400 VAC devices
3.1.4.
Ballast resistor / high voltage supply plug X2 for 230VAC
devices
22
PIN
Description
1
L1
2
L2
3
L3
4
PE
Mains connection Compax3 Sxxx V4
Controller type
Mains voltage
Rated input current
Maximum fuse rating per
device
Always switch devices off before wiring them!
Dangerous voltages are still present until 5 minutes after
switching off the power supply!
PIN
Description
1
+ Ballast resistor
2
- Ballast resistor
3
PE
4
+ DC high voltage supply
5
- DC high voltage supply
Caution! The connector assignment of X2 is changed!
Please note the screen printing on the front plate of the
device: this is valid
I11 T11 192-120101 N6 - March 2004
S038 V4
S075 V4
Three-phase 3*400VAC
80-480 VAC+10% / 50-60 Hz
6Aeff
10 Aeff
10A (automatic
16 A (automatic circuit
circuit breaker
breaker K)
K)
S150 V4
S300 V4
16Aeff
22Aeff
25A (automatic
circuit breaker
K)