Linear Motors; Torque Motors - Parker Compax3 Series Operating Instructions Manual

Positioning via digital i/os
Hide thumbs Also See for Compax3 Series:
Table of Contents

Advertisement

Parker EME
8.3.1.2
8.3.1.3
given as a percentage of the reference current). Note that values that are too high
will cause Error 0x73A6 to be triggered.
Typically the motor moves by 4% of the pitch length or, with rotary direct drives 4%
of 360°/number of pole pairs - maximum 50%.
Note the following conditions for automatic commutation
The linear motor must not be at the end limits for automatic commutation.
!
Actively working load torques are not permitted during automatic commutation.
!
Rubbing caused by friction deteriorates the effect of automatic commutation.
!
With the exception of missing commutation information, the controller/motor
!
combination is configured and ready for operation (parameters correctly assigned
for the linear motor/drive). The transmitter and the direction of the field of rotation
in effect must match.
The auto-commutating function must be adapted to fit the mechanics if necessary
!
during commissioning.

Linear motors

Parker offers you a number of systems of linear motor drives:
Linear motors
Linear motor kit SL:
Linear motors of the LXR series:
Linear motor module BLMA:

Torque motors

Parker offers you an extensive range of torque motors that can be adapted to your
application. Please contact us for information.
I11 T11 192-120101 N6 - March 2004
Feed force
(continuous/dynamic)
475N / 739N
315N / 1,000N
605N / 1,720N
Compax3 Accessories
Stroke length:
As required
Up to 3 m
Up to 6m
109