Parker EME
3.1.1.

Function of the LEDs on the front panel

3.1.2.

Power supply plug X1 for 230VAC devices

Caution!
When the control voltage is missing there is no indication whether or
not high voltage supply is available.
State
Voltages missing
While booting
No configuration present.
!
SinCos feedback not detected.
!
IEC program not compatible with the
!
firmware.
For F12: Hall signals invalid.
!
Axis without current excitation
Power supplied to axis; commutation calibration
running
Axis with current excitation
Axis in fault status / fault present
PIN
Description
1
L
2
N
3
PE
Mains connection: Compax3 S0xx V2
Controller type
Mains voltage
Rated input current
Maximum fuse rating per device
Always switch devices off before wiring them!
Dangerous voltages are still present until 5 minutes after
switching off the power supply!
I11 T11 192-120101 N6 - March 2004
Plug and connector assignment Compax3

Function of the LEDs on the front panel

LED red
off
alternately flashing
flashing
off
off
off
on
S025 V2
S063 V2
Single phase 230VAC + 10%
80-230VAC+10% / 50-60Hz
6Aeff
16Aeff
10A (automatic circuit
16 A (automatic circuit
breaker K)
breaker K)
LED green
off
off
Flashes slowly
Flashes quickly
on
off