Introduction - ILX Lightwave LDX-3200 Series User Manual

Precision current source
Table of Contents

Advertisement

CHAPTER 4
COMMAND REFERENCE

INTRODUCTION

This chapter is a guide to all of the device-dependent commands for the LDX-3200 Series Precision Current Source.
This chapter is divided into two parts. The first part contains an overview of the remote commands used by the
LDX-3200 Series Precision Current Source. The second part contains all of the LDX-3200 Series Precision Current
Source commands in alphabetical order. Figure 4.1 shows the format for the device command descriptions in this
chapter. The commands which emulate local (front panel) operation are denoted by the solid box next to the Local
label in the upper left corner of the command description.
NAME
PARAMETERS
DELAY
1
ERR?
NONE
LAS:CALMD
1
LAS:CALMD?
NONE
LAS:CAL:CONST?
1
LAS:CAL:LDI
NONE
LAS:CAL:LDI?
NONE
LAS:CAL:LDV
NONE
LAS:CAL:LDV?
NONE
LAS:CAL:MDI
NONE
LAS:CAL:MDI?
NONE
LAS:COND?
NONE
LAS:DEC
0, 1 or 2
LAS:DIS
1
LAS:DIS?
NONE
LAS:DIS:LDI
NONE
LAS:DIS:LDI?
NONE
LAS:DIS:LDV
NONE
LAS:DIS:LDV?
NONE
LAS:DIS:MDI
NONE
LAS:DIS:MDI?
NONE
LAS:DIS:MDP
NONE
LAS:DIS:MDP?
NONE
LAS:DIS:PARAM
NONE
LAS:DIS:SET
NONE
LAS:DIS:SET?
NONE
COMMAND REFERENCE
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
LDX-3200 SERIES DEVICE-DEPENDENT COMMANDS
FUNCTION
Used to create a delay in the execution of further commands.
Returns errors generated since the last query.
Used to set the CAL PD (monitor responsivity) constant.
Returns the CAL PD (monitor responsivity) constant.
Factory use only.
Used to enter the laser current calibration mode.
Returns the ready state for entering the laser current calibration value.
Used to enter the laser voltage calibration mode.
Returns the ready state for entering the laser voltage calibration value.
Used to enter the monitor photodiode current calibration mode.
Returns the ready state for entering the monitor PD current calibration
value.
Returns the value of the LASER condition register.
Used to decrease the laser current set point value by one or more steps.
Turns the LASER display on or off.
Returns the LASER display value.
Turn on/off LASER display to show laser output current.
Returns status of laser output current display, on/off.
Turn on/off LASER display to show laser output voltage.
Returns status of laser output voltage display, on/off.
Turn on/off LASER display to show PD monitor current.
Returns status of photo diode monitor current display, on/off.
Turns on/off LASER display to show PD monitor power.
Returns status of photodiode monitor power display, on/off.
Enables LASER display to show parameter values.
Shows the LASER display set point corresponding to mode
Returns status of LASER set point display, on/off.
Table 4.1 LDX-3200 Series Device-Dependent Commands