Beckhoff EL34 Series Documentation page 235

3-phase energy and power measurement terminals
Table of Contents

Advertisement

Index 1A24 Total TxPDO-Map Status
Index (hex) Name
1A24:0
Total TxPDO-Map
Status
1A24:01
SubIndex 001
1A24:02
SubIndex 002
1A24:03
SubIndex 003
1A24:04
SubIndex 004
1A24:05
SubIndex 005
1A24:06
SubIndex 006
1A24:07
SubIndex 007
1A24:08
SubIndex 008
1A24:09
SubIndex 009
1A24:0A
SubIndex 010
1A24:0B
SubIndex 011
1A24:0C
SubIndex 012
1A24:0D
SubIndex 013
1A24:0E
SubIndex 014
1A24:0F
SubIndex 015
1A24:10
SubIndex 016
Index 1A26 Total TxPDO-Map Advanced
Index (hex) Name
1A26:0
Total TxPDO-Map Ad-
vanced
1A26:01
SubIndex 001
1A26:02
SubIndex 002
1A26:03
SubIndex 003
1A26:04
SubIndex 004
1A26:05
SubIndex 005
1A26:06
SubIndex 006
1A26:07
SubIndex 007
1A26:08
SubIndex 008
EL34xx
Meaning
PDO Mapping TxPDO 31
1. PDO Mapping entry (object 0xF600 (PMX Total
Status), entry 0x01 (System State))
2. PDO Mapping entry (object 0xF600 (PMX Total
Status), entry 0x02 (Grid Direction))
3. PDO Mapping entry (object 0xF600 (PMX Total
Status), entry 0x03 (Frequency Guard Warning))
4. PDO Mapping entry (object 0xF600 (PMX Total
Status), entry 0x04 (Frequency Guard Error))
5. PDO Mapping entry (object 0xF600 (PMX Total
Status), entry 0x05 (Neutral Current Guard Warning))
6. PDO Mapping entry (object 0xF600 (PMX Total
Status), entry 0x06 (Neutral Current Guard Error))
7. PDO Mapping entry (object 0xF600 (PMX Total
Status), entry 0x07 (Active Power Guard Warning))
8. PDO Mapping entry (object 0xF600 (PMX Total
Status), entry 0x08 (Active Power Guard Error))
9. PDO Mapping entry (object 0xF600 (PMX Total
Status), entry 0x09 (Apparent Power Guard Warn-
ing))
10. PDO Mapping entry (object 0xF600 (PMX Total
Status), entry 0x0A (Apparent Power Guard Error))
11. PDO Mapping entry (object 0xF600 (PMX Total
Status), entry 0x0B (Power Quality Guard Warning))
12. PDO Mapping entry (object 0xF600 (PMX Total
Status), entry 0x0C (Power Quality Guard Error))
13. PDO Mapping entry (2 bits align)
14. PDO Mapping entry (object 0xF600 (PMX Total
Status), entry 0x0F (TxPDO State))
15. PDO Mapping entry (object 0xF600 (PMX Total
Status), entry 0x10 (TxPDO Toggle))
16. PDO Mapping entry (object 0xF600 (PMX Total
Status), entry 0x11 (Power Quality Factor))
Meaning
PDO Mapping TxPDO 33
1. PDO Mapping entry (object 0xF602 (PMX Grid Ad-
vanced), entry 0x11 (Max Voltage Harmonic Distor-
tion))
2. PDO Mapping entry (object 0xF602 (PMX Grid Ad-
vanced), entry 0x12 (Max Current Harmonic Distor-
tion))
3. PDO Mapping entry (object 0xF602 (PMX Grid Ad-
vanced), entry 0x13 (Max Current Distortion Factor))
4. PDO Mapping entry (object 0xF602 (PMX Grid Ad-
vanced), entry 0x14 (Voltage Unbalance))
5. PDO Mapping entry (object 0xF602 (PMX Total
Advanced), entry 0x11 (Max Voltage Harmonic Dis-
tortion))
6. PDO Mapping entry (object 0xF602 (PMX Total
Advanced), entry 0x12 (Max Current Harmonic Dis-
tortion))
7. PDO Mapping entry (object 0xF602 (PMX Total
Advanced), entry 0x13 (Max Current Distortion Fac-
tor))
8. PDO Mapping entry (object 0xF602 (PMX Total
Advanced), entry 0x14 (Voltage Unbalance))
Version: 1.5
Commissioning
Data type
Flags
Default
UINT8
RO
0x10 (16
UINT32
RO
0xF600:01, 1
UINT32
RO
0xF600:02, 1
UINT32
RO
0xF600:03, 1
UINT32
RO
0xF600:04, 1
UINT32
RO
0xF600:05, 1
UINT32
RO
0xF600:06, 1
UINT32
RO
0xF600:07, 1
UINT32
RO
0xF600:08, 1
UINT32
RO
0xF600:09, 1
UINT32
RO
0xF600:0A, 1
UINT32
RO
0xF600:0B, 1
UINT32
RO
0xF600:0C, 1
UINT32
RO
0x0000:00, 2
UINT32
RO
0xF600:0F, 1
UINT32
RO
0xF600:10, 1
UINT32
RO
0xF600:11, 32
Data type
Flags
Default
UINT8
RO
0x08 (8
UINT32
RO
0xF602:01, 1
UINT32
RO
0xF602:02, 1
UINT32
RO
0x0000:00, 13
UINT32
RO
0xF602:10, 1
UINT32
RO
0xF602:11, 32
UINT32
RO
0xF602:12, 32
UINT32
RO
0xF602:13, 32
UINT32
RO
0xF602:14, 32
)
dec
)
dec
235

Hide quick links:

Advertisement

Table of Contents
loading