Beckhoff EL34 Series Documentation page 231

3-phase energy and power measurement terminals
Table of Contents

Advertisement

Index 1App TxPDO-Map Status (for L1, pp = 00; L2, pp = 0C; L3, pp = 18)
Index (hex) Name
1App:0
TxPDO-Map Status
1App:01
SubIndex 001
1App:02
SubIndex 002
1App:03
SubIndex 003
1App:04
SubIndex 004
1App:05
SubIndex 005
1App:06
SubIndex 006
1App:07
SubIndex 007
1App:08
SubIndex 008
1App:09
SubIndex 009
1App:0A
SubIndex 010
1App:0B
SubIndex 011
**) for L1, n = 0; L2, n = 1; L3, n = 2)
Index 1App TxPDO-Map Basic (for L1, pp = 01; L2, pp = 0D; L3, pp = 19)
Index (hex) Name
1App:0
TxPDO-Map Statistic
Basic
1App:01
SubIndex 001
1App:02
SubIndex 002
**) for L1, n = 0; L2, n = 1; L3, n = 2)
Index 1App TxPDO-Map Power (for L1, pp = 02; L2, pp = 0E; L3, pp = 1A)
Index (hex) Name
1App:0
TxPDO-Map Power
1App:01
SubIndex 001
1App:02
SubIndex 002
1App:03
SubIndex 001
1App:04
SubIndex 002
**) for L1, n = 0; L2, n = 1; L3, n = 2)
EL34xx
Meaning
PDO Mapping TxPDO
1. PDO Mapping entry (object 0x60n0 (PMX Status),
entry 0x01 (Voltage Sign Bit))
2. PDO Mapping entry (object 0x60n0 (PMX Status),
entry 0x02 (Overvoltage))
3. PDO Mapping entry (object 0x60n0 (PMX Status),
entry 0x03 (Overcurrent))
4. PDO Mapping entry (object 0x60n0 (PMX Status),
entry 0x04 (Inaccurate Voltage))
5. PDO Mapping entry (object 0x60n0 (PMX Status),
entry 0x05 (Inaccurate Current))
6. PDO Mapping entry (object 0x60n0 (PMX Status),
entry 0x06 (Voltage Guard Warning))
7. PDO Mapping entry (object 0x60n0 (PMX Status),
entry 0x07 (Voltage Guard Error))
8. PDO Mapping entry (object 0x60n0 (PMX Status),
entry 0x08 (Current Guard Warning))
9. PDO Mapping entry (object 0x60n0 (PMX Status),
entry 0x09 (Current Guard Error))
10. PDO Mapping entry (6 bits align)
11. PDO Mapping entry (object 0x60n0 (PMX Sta-
tus), entry 0x10 (TxPDO Toggle))
Meaning
PDO Mapping TxPDO
1. PDO Mapping entry (object 0x60n1 (PMX Basic),
entry 0x11 (Voltage))
2. PDO Mapping entry (object 0x60n1 (PMX Basic),
entry 0x12 (Current))
Meaning
PDO Mapping TxPDO
1. PDO Mapping entry (object 0x60n2 (PMX Power),
entry 0x11 (Active Power))
2. PDO Mapping entry (object 0x60n2 (PMX Power),
entry 0x12 (Apparent Power))
1. PDO Mapping entry (object 0x60n2 (PMX Power),
entry 0x13 (Reactive Power))
2. PDO Mapping entry (object 0x60n2 (PMX Power),
entry 0x14 (Power Factor))
Version: 1.5
Commissioning
Data type
Flags
Default
UINT8
RO
0x0B (11
UINT32
RO
0x60n0:01, 1**
UINT32
RO
0x60n0:02, 1**
UINT32
RO
0x60n0:03, 1**
UINT32
RO
0x60n0:04, 1**
UINT32
RO
0x60n0:05, 1**
UINT32
RO
0x60n0:06, 1**
UINT32
RO
0x60n0:07, 1**
UINT32
RO
0x60n0:08, 1**
UINT32
RO
0x60n0:09, 1**
UINT32
RO
0x00n0:00, 6**
UINT32
RO
0x60n0:10, 1**
Data type
Flags
Default
UINT8
RO
0x02 (2
UINT32
RO
0x60n1:11, 32**
UINT32
RO
0x60n1:12, 32**
Data type
Flags
Default
UINT8
RO
0x04 (4
UINT32
RO
0x60n2:11, 32**
UINT32
RO
0x60n2:12, 32**
UINT32
RO
0x60n2:13, 32**
UINT32
RO
0x60n2:14, 32**
)
dez
)