Index 80n2 PMX User Scale (for ch.1, n = 0; ch.2, n = 1; ch.3, n = 2)
Index (hex) Name
80n2:0
PMX User Scale Ch.1 Max. subindex
80n2:01
User Calibration En-
able
80n2:11
User Calibration Volt-
age Offset
80n2:12
User Calibration Volt-
age Gain
80n2:13
User Calibration Cur-
rent Offset
80n2:14
User Calibration Cur-
rent Gain
80n2:15
User Calibration
Phase Offset
Index F800 PMX Settings
Index (hex) Name
F800:0
PMX Settings
F800:01
Reset Interval
F800:11
Reference
F800:12
Measurement Range Filter setting for determining the fundamental
F800:13
Frequency Source
F800:14
Power Calculation
Threshold
F800:15
Inaccurate Threshold
Voltage
F800:16
Inaccurate Threshold
Current
Index F801 PMX Total Settings PQF
Index (hex) Name
F801:0
PMX Total Settings
PQF
F801:11
Nominal voltage
F801:12
Nominal Frequency
F801:13
PQF Dataset
182
Meaning
Set to true to enable user calibration data.
Value in V
Factor (without unit)
Value in A
Factor (without unit)
Value in milliseconds
Meaning
Max. subindex
Manual restart of the measurement and statistics in-
terval
Timing reference for the RMS calculation
Set to "Current" if a current is to be measured without
an applied voltage.
permitted values:
0
Voltage (default)
1
Current
permitted values:
0
25..65 Hz (default)
1
25..400 Hz
2
12..45 Hz
Source of the system frequency
permitted values:
0
Channel 1 (default)
1
Channel 2
2
Channel 3
Noise reduction:
Here you can enter a minimum limit value in percent
for the power calculation, below which all values are
zeroed.
Limit value for the warning bit: Inaccurate Voltage
Limit value for the warning bit: Inaccurate Current
Meaning
Max. subindex
A nominal voltage value or set value is required to
calculate the power quality factor (for details see ba-
sic function principles).
A nominal frequency or set value is required to calcu-
late the power quality factor (for details see basic
function principles).
permitted values:
0: default
1: default + unbalace
Version: 1.5
Data type
Flags
Default
UINT8
RO
0x15 (21
BOOLEAN
RW
0x00 (0
REAL32
RW
0x00000000 (0
REAL32
RW
0x3F800000
(1065353216
REAL32
RW
0x00000000 (0
REAL32
RW
0x3F800000
(1065353216
REAL32
RW
0x00000000 (0
Data type
Flags
Default
UINT8
RO
0x16 (22
BOOLEAN
RW
0x00 (0
UINT32
RW
0x00000000 (0
UINT32
RW
0x00000000 (0
BIT1
RW
0x00000000 (0
REAL32
RW
0x3F800000
(1065353216
REAL32
RW
0x3FDC28F6
(1071393014
REAL32
RW
0x3BC49BA6
(1002740646
Data type
Flags
Default
UINT8
RO
0x13 (19
REAL32
RW
0x43660000
(1130758144
REAL32
RW
0x42480000
(1112014848
UINT32
RW
0x00000001 (0
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
EL34xx