Beckhoff EL34 Series Documentation page 175

3-phase energy and power measurement terminals
Table of Contents

Advertisement

Index 1A28 Total TxPDO-Map Total Interval Energy
Index (hex) Name
1A28:0
Total TxPDO-Map To-
tal Interval Energy
1A28:01
SubIndex 001
1A28:02
SubIndex 002
1A28:03
SubIndex 003
1A28:04
SubIndex 004
1A28:05
SubIndex 005
1A28:06
SubIndex 006
1A28:07
SubIndex 007
1A28:08
SubIndex 008
1A28:09
SubIndex 009
1A28:0A
SubIndex 010
1A28:0B
SubIndex 011
Index 1A29 Total TxPDO-Map Active Reduced
Index (hex) Name
1A29:0
Total TxPDO-Map Ac-
tive Reduced
1A29:01
SubIndex 001
1A29:02
SubIndex 002
Index 1A2A Total TxPDO-Map Apparent Reduced
Index (hex) Name
1A2A:0
Total TxPDO-Map Ap-
parent Reduced
1A2A:01
SubIndex 001
1A2A:02
SubIndex 002
Index 1A2B Total TxPDO-Map Reactive Reduced
Index (hex) Name
1A2B:0
Total TxPDO-Map
Reactive Reduced
1A2B:01
SubIndex 001
1A2B:02
SubIndex 002
EL34xx
Meaning
PDO Mapping TxPDO 41
1. PDO Mapping entry (15 bits align)
2. PDO Mapping entry (object 0xF60D (PMX Total In-
terval Energy), entry 0x10 (TxPDO Toggle))
3. PDO Mapping entry (object 0xF60D (PMX Total In-
terval Energy), entry 0x11 (Active Energy))
4. PDO Mapping entry (object 0xF60D (PMX Total In-
terval Energy), entry 0x12 (Active Energy Positive))
5. PDO Mapping entry (object 0xF60D (PMX Total In-
terval Energy), entry 0x13 (Active Energy Negative))
6. PDO Mapping entry (object 0xF60D (PMX Total In-
terval Energy), entry 0x14 (Apparent Energy))
7. PDO Mapping entry (object 0xF60D (PMX Total In-
terval Energy), entry 0x15 (Apparent Energy Posi-
tive))
8. PDO Mapping entry (object 0xF60D (PMX Total In-
terval Energy), entry 0x16 (Apparent Energy Nega-
tive))
9. PDO Mapping entry (object 0xF60D (PMX Total In-
terval Energy), entry 0x17 (Reactive Energy))
10. PDO Mapping entry (object 0xF60D (PMX Total
Interval Energy), entry 0x18 (Reactive Energy Posi-
tive))
11. PDO Mapping entry (object 0xF60D (PMX Total
Interval Energy), entry 0x19 (Reactive Energy Nega-
tive))
Meaning
PDO Mapping TxPDO 35
1. PDO Mapping entry (Alignet))
2. PDO Mapping entry (object 0xF612 (PMX Total
Apparent), entry 0x12 (Active Reduced))
Meaning
PDO Mapping TxPDO 35
1. PDO Mapping entry (object 0xF613 (PMX Total
Apparent Reduced), entry 0x11 (Apparent Power))
2. . PDO Mapping entry (object 0xF613 (PMX Total
Apparent Reduced), entry 0x12 (Apparent Energy))
Meaning
PDO Mapping TxPDO 36
1. PDO Mapping entry (object 0xF614 (PMX Total
Reactive Reduced), entry 0x11 (Reactive Power))
2. PDO Mapping entry (object 0xF614 (PMX Total
Reactive Reduced), entry 0x12 (Reactive Energy))
Version: 1.5
Commissioning
Data type
Flags
Default
UINT8
RO
0x0B (11
UINT32
RO
0x0000:00, 15
UINT32
RO
0xF60D:10, 1
UINT32
RO
0xF60D:11, 32
UINT32
RO
0xF60D:12, 32
UINT32
RO
0xF60D:13, 32
UINT32
RO
0xF60D:14, 32
UINT32
RO
0xF60D:15, 32
UINT32
RO
0xF60D:16, 32
UINT32
RO
0xF60D:17, 32
UINT32
RO
0xF60D:18, 32
UINT32
RO
0xF60D:19, 32
Data type
Flags
Default
UINT8
RO
0x02 (2
UINT32
RO
0x0000:00, 32
UINT32
RO
0xF612:12, 64
Data type
Flags
Default
UINT8
RO
0x02 (2
UINT32
RO
0xF613:11, 32
UINT32
RO
0xF613:12, 64
Data type
Flags
Default
UINT8
RO
0x02 (2
UINT32
RO
0xF614:11, 32
UINT32
RO
0xF614:12, 64
)
dec
)
dec
)
dec
)
dec
175