Beckhoff EL34 Series Documentation page 189

3-phase energy and power measurement terminals
Table of Contents

Advertisement

Index F603 PMX Total Active
Index (hex) Name
F603:0
PMX Total Active
F603:11
Active Power
F603:12
Active Energy
F603:13
Active Positive Energy Received active energy in mWh
F603:14
Active Negative En-
ergy
Index F605 PMX Total Apparent
Index (hex) Name
F605:0
PMX Total Apparent
F605:11
Apparent Power
F605:12
Apparent Energy
F605:13
Apparent Positive En-
ergy
F605:14
Apparent Negative
Energy
Index F607 PMX Total Reactive
Index (hex) Name
F607:0
PMX Total Reactive
F607:11
Reactive Power
F607:12
Reactive Energy
F607:13
Reactive Positive En-
ergy
F607:14
Reactive Negative
Energy
Index F609 PMX Total L-L Voltages
Index (hex) Name
F609:0
PMX Total L-L Volt-
ages
F609:11
L1-L2 Voltage
F609:12
L2-L3 Voltage
F609:13
L3-L1 Voltage
Index F60A PMX Variant Value In
Index (hex) Name
F60A:0
PMX Variant Value In Max. subindex
F60A:10
TxPDO Toggle
F60A:11
Index 1 REAL
F60A:12
Value 1 REAL
F60A:13
Index 2 REAL
F60A:14
Value 2 REAL
F60A:15
Index 3 REAL
F60A:16
Value 3 REAL
F60A:17
Index 4 ULINT
F60A:18
Value 4 ULINT
EL34xx
Meaning
Max. subindex
Active power in W
Recorded active energy in mWh
Supplied active energy in mWh
Meaning
Max. subindex
Balanced apparent power in VA
Recorded apparent energy in mWh
Received apparent energy in mWh
Supplied apparent energy in mWh
Meaning
Max. subindex
Balanced reactive power in Var
Recorded reactive energy in mWh
Received reactive energy in mWh
Supplied reactive energy in mWh
Meaning
Max. subindex
RMS value of the phase-to-phase voltage between
L1 and L2 in V
RMS value of the phase-to-phase voltage between
L2 and L3 in V
RMS value of the phase-to-phase voltage between
L3 and L1 in V
Meaning
The TxPDO toggle is toggled by the slave when the
data of the associated TxPDO is updated.
Acknowledge for variable output value 1
variable output value channel 1
Acknowledge for variable output value 2
variable output value channel 2
Acknowledge for variable output value 3
variable output value channel 3
Acknowledge for variable output value 4
variable output value channel 4
Version: 1.5
Commissioning
Data type
Flags
Default
UINT8
RO
0x14 (20
INT64
RO
INT64
RO
INT64
RO
INT64
RO
Data type
Flags
Default
UINT8
RO
0x14 (20
INT64
RO
INT64
RO
UINT64
RO
UINT64
RO
Data type
Flags
Default
UINT8
RO
0x14 (20
INT64
RO
INT64
RO
UINT64
RO
UINT64
RO
Data type
Flags
Default
UINT8
RO
0x13 (19
REAL32
RO
0x00000000 (0
REAL32
RO
0x00000000 (0
REAL32
RO
0x00000000 (0
Data type
Flags
Default
UINT8
RO
0x18 (24
BOOLEAN
RO
0x00 (0
UINT16
RO
0x0000 (0
REAL32
RO
0x00000000 (0
UINT16
RO
0x0000 (0
REAL32
RO
0x00000000 (0
UINT16
RO
0x0000 (0
REAL32
RO
0x00000000 (0
UINT16
RO
0x0000 (0
UINT64
RO
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
189