Index A0n0 PMX Diag data (for ch.1, n = 0; ch.2, n = 1; ch.3, n = 2)
Index (hex) Name
A0n0:0
PMX diag data ch.1
A0n0:11
Saturation Time Volt-
age
A0n0:12
Saturation Time Cur-
rent
Index F081 Download revision
Index (hex) Name
F081:0
Download revision
F010:01
Revision number
Index F80F PMX vendor data (for ch.1, n = 0; ch.2, n = 1; ch.3, n = 2)
Index (hex) Name
F80F:0
PMX Vendor data
F80F:11
Type
F80F:12
Calibration Current
Offset
F80F:13
Calibration Current
Gain
F80F:14
Calibration Current
Phase Offset
F80F:15
Calibration Current 1
Offset
F80F:16
Calibration Current 1
Gain
F80F:17
Calibration Current 1
Phase Offset
F80F:18
Calibration Current 2
Offset
F80F:19
Calibration Current 2
1 Gain
F80F:1A
Calibration Current 2
Phase Offset
Index F902 PMX Total Info data Power
Index (hex) Name
F902:0
PMX Total Info data
Power
F902:11
Active Power Avg
F902:12
Active Power Min
F902:13
Active Power Max
F902:14
Apparent Power Avg
F902:15
Apparent Power Min
F902:16
Apparent Power Max Maximum total apparent power in the last interval in
F902:17
Reactive Power Avg
F902:18
Reactive Power Min
F902:19
Reactive Power Max
EL34xx
Meaning
Max. subindex
Time (in 0.1 ms) in which the terminal has measured
an overvoltage.
Time (in 0.1 ms) in which the terminal has measured
an overcurrent.
Meaning
Max. subindex
Configured revision of the terminal,
(see note)
Meaning
Max. subindex
Vendor-specific data
Value in A
Factor (without unit)
Value in milliseconds
Value in A
Factor (without unit)
Value in milliseconds
Value in A
Factor (without unit)
Value in milliseconds
Meaning
Max. subindex
Average total active power during the last interval in
W
Minimum total active power in the last interval in W
Maximum total active power in the last interval in W
Average total apparent power during the last interval
in VA
Minimum total apparent power in the last interval in
VA
VA
Average total reactive power average during the last
interval in var
Minimum total reactive power in the last interval in
var
Maximum total reactive power in the last interval in
var
Version: 1.5
Commissioning
Data type
Flags
Default
UINT8
RO
0x12 (18
UINT32
RO
0x00000000 (0
UINT32
RO
0x00000000 (0
Data type
Flags
Default
UINT8
RO
0x01 (1
UINT32
RW
0x00000000 (0
Data type
Flags
Default
UINT8
RO
0x1A (26
UINT32
RW
0x00000000
REAL32
RW
0,000000
(0,000000e+000)
REAL32
RW
1,000000
(1,000000e+000)
REAL32
RW
0,000000
(0,000000e+000)
REAL32
RW
0,000000
(0,000000e+000)
REAL32
RW
1,000000
(1,000000e+000)
REAL32
RW
0,000000
(0,000000e+000)
REAL32
RW
0,000000
(0,000000e+000)
REAL32
RW
1,000000
(1,000000e+000)
REAL32
RW
0,000000
(0,000000e+000)
Data type
Flags
Default
UINT8
RO
0x19 (25
REAL32
RO
0x00000000 (0
REAL32
RO
0x00000000 (0
REAL32
RO
0x00000000 (0
REAL32
RO
0x00000000 (0
REAL32
RO
0x00000000 (0
REAL32
RO
0x00000000 (0
REAL32
RO
0x00000000 (0
REAL32
RO
0x00000000 (0
REAL32
RO
0x00000000 (0
)
dec
)
dec
)
dec
)
dec
)
dec
)
dez
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
)
dec
227