Loads on foundation, robot
The table shows the various forces and torques working on the robot during different
kinds of operation.
Floor mounted
Force
Force xy
Force z
Torque xy
Torque z
Requirements, foundation
The table shows the requirements for the foundation where the weight of the
installed robot is included:
Requirement
Flatness of foundation
surface
Maximum tilt
Product manual - IRB 1410
3HAC026320-001 Revision: N
Note
The weight does not include tools and other equipment fitted on the robot.
Note
These forces and torques are extreme values that are rarely encountered during
operation. The values also never reach their maximum at the same time!
WARNING
The robot installation is restricted to the mounting options given in following load
table(s).
Endurance load (in operation)
±1500 N
2800 ±500 N
±1800 Nm
±400 Nm
Value
0.5
55°
© Copyright 2006-2018 ABB. All rights reserved.
2 Installation and commissioning
2.2.1 Pre-installation procedure
Max. load (emergency stop)
±2000 N
2800 ±700 N
±2000 Nm
±500 Nm
Note
Flat foundations give better repeatability of the
resolver calibration compared to original settings
on delivery from ABB.
The value for levelness aims at the circumstance
of the anchoring points in the robot base.
In order to compensate for an uneven surface,
the robot can be recalibrated during installation.
If resolver/encoder calibration is changed this
will influence the absolute accuracy.