ACS380 FW.book Page 284 Friday, May 4, 2018 4:18 PM
284 Parameters
No.
Name/Value
Supervision 3
Supervision 4
Supervision 5
Supervision 6
Other [bit]
44.208 Safety close speed
0.00 ...
30000.00 rpm
44.209 Safety close delay
0...30000 ms
44.211
Extended runtime
0.0...3600.0 s
44.212 Extended runtime sw
Bit
Name
0
Extended run in operation
1
Extended run enabled
2...15
Reserved
0000h...FFFFh
45

45 Energy efficiency

45.01
Saved GW hours
0...65535 GWh
ghv Vertriebs-GmbH | Am Schammacher Feld 47 | 85567 Grafing | Telefon + 49 80 92 81 89 0 | info@ghv.de | www.ghv.de
Description
Bit 2 of
32.01 Supervision
status.
Bit 3 of
32.01 Supervision
status.
Bit 4 of
32.01 Supervision
status.
Bit 5 of
32.01 Supervision
status.
Source selection (see
Terms and abbreviations
112).
Defines the speed limit for the Brake safe closure function.
Brake safe closure speed.
Defines the time delay before the drive trips on fault
Brake safe
closure.
Time delay.
Defines the time period during which drive keeps the
motor magnetized after the brake is closed. The Extended
run time function is enabled if this value is less than 3600
seconds or greater than 0 seconds.
Note: The extended run time function is active only when
all these conditions are satisfied:
• the drive is set to vector motor control mode (see page
54)
• the drive is in Remote control
WARNING! Extended runtime causes the
motor to heat up. In cases where long
magnetization time is required, make sure to use
motors with external ventilation.
Time period.
Shows the status of the Extended runtime function.
This parameter is read-only.
Description
0 = Extended run time is active.
1= Extended run time is not active.
1 = Extended run time function is enabled.
0 = Extended run time function is disabled.
Extended runtime status.
Settings for the energy saving calculators.
See also section
Energy saving calculators
Energy saved in GWh compared to direct-on-line motor
connection. This parameter is incremented when
Saved MW hours
rolls over.
This parameter is read-only (see parameter
calculations
reset).
Energy savings in GWh.
Default
FbEq 16
26
27
28
29
on page
-
50.00 rpm
1 = 1 rpm
D102
2000 ms
1 = 1 ms
0.0 s
10 = 1 s
0000h
-
(page 104).
-
45.02
45.21 Energy
1 = 1 GWh