Energy Efficiency Data (Ecodesign); Cooling; Degree Of Protection; Agps-11C (Option +Q950) - ABB ACS800-U1 Hardware Manual

Hide thumbs Also See for ACS800-U1:
Table of Contents

Advertisement

Energy efficiency data (ecodesign)

Cooling

Method
Free space around the
unit

Degree of protection

AGPS-11C (option +Q950)

Nominal input voltage
Nominal input current
Nominal frequency
Max. external fuse
X1 terminal sizes
Output voltage
Nominal output current
X2 terminal block type
Degree of protection
Ambient temperature
Relative humidity
Dimensions (with
enclosure)
Weight (with enclosure)
Approvals

ASTO-11C (option +Q967)

Supply voltage range
Current consumption
Supply cable
Maximum cable length
Conductor min. cross
section
X1 terminal sizes
Nominal output current
X2 terminal block type
Degree of protection
Ambient temperature
Relative humidity
Altitude in operation
Dimensions (with
enclosure)
Weight (with enclosure)
Energy efficiency data according to IEC 61800-9-2 is available from the
ecodesign tool (https://ecodesign.drivesmotors.abb.com).
Internal fan, flow direction from bottom to top.
Mechanical installation
See
IP21 (UL type 1) and IP55 (UL type 12). Without the connection box and front
cover, the unit must be protected against contact according to IP2x [see
Cabinet installation (IP21, UL type 1)
115...230 V AC ±10%
0.1 A (230 V) / 0.2 A (115 V)
50/60 Hz
16 A
2
3 x 2.5 mm
15 V DC ±0.5 V
0.4 A
JST B4P-VH
IP20
0...50 °C (32...122 °F)
Max. 90%, no condensation allowed
167 x 128 x 52 mm (height x weight x depth)
0.75 kg (1.65 lb)
C-UL, US listed
+24 V DC +/- 10%
40 mA (20 mA per channel)
A single-shielded twisted pair
300 m
2
0.5 mm
, 20 AWG
2
4 x 2.5 mm
0.4 A
JST B4P-VH
IP20
0...50 °C (32...122 °F)
Max. 90%, no condensation allowed
0...2000 m (6562 ft)
167 x 128 x 52 mm (height x weight x depth)
0.75 kg (1.65 lb)
(page 27).
on page 68].
Technical data 125

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs800-01