Download Print this page

I/O Extension Module - ABB ACS380 Firmware Manual

Machinery control program
Hide thumbs Also See for ACS380:

Advertisement

ACS380 FW.book Page 149 Friday, May 4, 2018 4:18 PM
No.
Name/Value
13.20
AO1 out at AO1 src
max
0.000...22.000 mA
0.000...11.000 V
13.91
AO1 data storage
-327.68 ... 327.67
15

15 I/O extension module

15.01
Extension module type
None
BREL
BAPO-01
BTAC-02
15.02
Detected extension
module
None
BREL
BAPO-01
BTAC-02
15.04
RO status
Bit
0
1
2
3
4...15
0000h...FFFFh
ghv Vertriebs-GmbH | Am Schammacher Feld 47 | 85567 Grafing | Telefon + 49 80 92 81 89 0 | info@ghv.de | www.ghv.de
Description
Defines the maximum output value for analog output AO1.
See also drawing at parameter
Maximum AO1 output value.
Storage parameter for controlling analog output AO1 eg.
through the embedded fieldbus interface.
In parameter
13.12 AO1
Then set this parameter as the target of the incoming
value data. With the embedded fieldbus interface, set the
target selection parameter of that particular data
(58.101...58.114
to
AO1 data
Storage parameter for AO1.
Configuration of the I/O extension module.
Note: The contents of the parameter group vary according
to the selected I/O extension module type.
Activates (and specifies the type of) I/O extension module.
If the value is None, when an extension module has been
installed and the dive is powered, the drive automatically
sets the value to the type it has detected (= value of
parameter
15.02 Detected extension
warning
A7AB Extension I/O configuration failure
generated and you have to set the value of this parameter
manually.
Inactive.
External relay option BREL-01.
Auxiliary power extension module option BAPO-01.
BTAC-02 pulse encoder interface module option BTAC-
02.
Shows the I/O extension module that the control program
has automatically detected on the drive.
Inactive.
External relay option BREL-01.
Auxiliary power extension module option BAPO-01.
Pulse encoder interface module option BTAC-02.
Displays the status of the relay outputs RO2, RO3, RO4
and RO5 on the extension module.
Value
Status of RO2 (1= relay closed, 0=relay open)
Status of RO3 (1= relay closed, 0=relay open)
Status of RO4 (1= relay closed, 0=relay open)
Status of RO5 (1= relay closed, 0=relay open)
Reserved
Status of relay outputs.
Parameters
Default
FbEq 16
20.000 mA
13.17 AO1 source
min.
1000 = 1 mA
0.00
source, select
AO1 data
storage.
storage).
100 = 1
None
module); otherwise
is
0
5
6
7
None
0
5
6
7
-
1 = 1
149

Hide quick links:

Advertisement

loading