Download Print this page

Application Features - ABB ACS380 Firmware Manual

Machinery control program
Hide thumbs Also See for ACS380:

Advertisement

ACS380 FW.book Page 322 Friday, May 4, 2018 4:18 PM
322 Parameters
No.
Name/Value
0.0...200000.0
71.40
Deadband delay
0.0...3600.0 s
71.58
Increase prevention
71.59
Decrease prevention
71.62
Internal setpoint actual
76

76 Application features

76.01
Limit to limit control
status
Not initialized
Rev zero, Fwd max
speed
Rev safe, Fwd max
speed
Rev max, Fwd max
speed
Rev max, Fwd safe
speed
Rev max, Fwd zero
speed
Rev safe,
Fwd zero speed
Rev zero,
Fwd safe speed
Rev safe,
Fwd safe speed
Rev zero,
Fwd zero speed
0...9
76.02
Enable limit to limit
control
Not selected
Selected
DI1
DI2
DI3
DI4
ghv Vertriebs-GmbH | Am Schammacher Feld 47 | 85567 Grafing | Telefon + 49 80 92 81 89 0 | info@ghv.de | www.ghv.de
Description
Range
Defines the deadband delay for the deadband function.
See parameter
71.39 Deadband
range.
Delay
See parameter
40.58 Set 1 increase
See parameter
40.59 Set 1 decrease
See parameter
40.62 PID internal setpoint
Application parameters.
See also section
Limit to limit control
Conical motor control
on page 563.
Displays the state of the Limit to limit control state
machine.
The initial value of the state machine.
The reverse speed is limited to zero speed, and the
forward direction speed is not limited by Limit to limit
control.
The reverse speed is limited to safe speed, and the
forward direction speed is not limited by Limit to limit
control.
The reverse speed is not limited, and the forward direction
speed is not limited by Limit to limit control.
The reverse speed is not limited, and the forward direction
speed is limited to safe speed by Limit to limit control.
The reverse speed is not limited, and the forward direction
speed is limited to zero speed by Limit to limit control.
The reverse speed is limited to safe speed, and the
forward direction speed is limited to zero speed by Limit to
limit control.
The reverse speed is limited to zero speed, and the
forward direction speed is limited to safe speed by Limit to
limit control.
The reverse speed is limited to safe speed, and the
forward direction speed is limited to safe speed by Limit to
limit control.
The reverse speed is limited to zero speed, and the
forward direction speed is limited to zero speed by Limit to
limit control.
Enables the Limit to limit control or selects the source for
limit to limit control function. For more information on the
function, see section
Limit to limit control
The Limit to limit control function is disabled.
The Limit to limit control function is enabled.
Digital input DI1
(10.02 DI delayed
status, bit 0)
Digital input DI2
(10.02 DI delayed
status, bit 1)
Digital input DI3
(10.02 DI delayed
status, bit 2)
Digital input DI4
(10.02 DI delayed
status, bit 3)
Default
FbEq 16
1 = 1
0.0 s
1 = 1 s
prevention.
No
prevention.
No
actual.
-
on page
94
and
Not
initialized
0
1
2
3
4
5
6
7
8
9
1 = 1
Not selected
on page 94.
0
1
2
3
4
5

Hide quick links:

Advertisement

loading