6.2.1 Menu list

The following are the menu items. Adjust each setting as required.
Item
1
TAG No.
2
Model code
3
Serial No.
4
Engineering unit
5
Range limit
6
Measuring range
7
Damping
8
Output mode
Direction and value of
9
burnout
A
Zero/span calibration
B
Output circuit calibration
D
Self-diagnosis
Locking of adjustment
F
functions
LCD display
G
range setting
Input-output range ad-
I
justment
Value and specification
J
of saturation current
Protective function of
K
set value
L
History information
*1: If the write protect is selected at "K. GUARD," the display for selecting whether the setting will be performed does not ap-
pear, but "GUARD" appears. You cannot change the value in this condition.
*2: If the adjustment function is locked at "F.Lock" or the write protect is selected at "K. GUARD," the item names is not displayed.
*3: Only differential pressure transmitters have this function. Other transmitters do not display the item name.
*6: This item is valid only if polygonal line correction is invalid. If the polygonal line correction is valid or the equipment is de-
fective, the item name is not displayed.
*8: In the multidrop mode, this item is invalid and the item name is not displayed.
*9: If the write protect function (with a password) is selected by the HHC, the item name is not displayed.
42
Item name
1. TAG
Display and setting of TAG No. (*1)
2. TYPE
Display and setting of type (*1)
3-1. SERIAL N
Display of serial No.
3-2. VER
Display of transmitter software version
4. UNIT
Display and change of engineering unit (*1)
5. URL
Display of maximum measuring range
Change of LRV
6-1. LRV
6-2. URV
(*1)
7. DAMP
Change of damping time constant (*1)
8-1. OUT Md
Change of output mode (*3) (*1)
8-2. CUT Pt
8-3. CUT Md
9-1. BURNOT
Change of burnout direction (*1)
9-2. OVER
OVERSCALE (*4) (*1)
9-3. UNDER
UNDERSCALE (*5) (*1)
A-1. ZERO
Zero calibration (*6) (*2)
A-2. SPAN
Span calibration (*6) (*2)
b-1. 4mAAdj
4 mA calibration (*8) (*2)
b-2. 20mAAdj
20 mA calibration (*8) (*2)
b-3. FIXcur
Constant current output (*8)
d-1. AMPTMP
Display of internal temperature of transmitter
d-2. ALMCHK
Display of self diagnosis.
Locking and unlocking of the adjusting screw and the adjustment func-
F. LOCK
tion in the setting mode (*1)
G-1. LDV
LDV (Lower Display Value) setting (*1)
G-2. UDV
UDV (Upper Display Value) setting (*1)
G-3. DP
DP (number of digit after Decimal Point) setting (*1)
G-4. LcdUnit
LcdUnit (LCD Unit Code) setting (*1)
G-5. LcdoOpt
LcdOpt (LCD Option) setting (*1)
I-1. LRVAdj
Zero adjustment by range (LRV) change (*6) (*2)
I-2. URVAdj
Span adjustment by range (URV) change (*6) (*2)
J-1. SAT LO
Change of saturation current value (lower limit) (*7) (*1)
J-2. SAT HI
Change of saturation current value (upper limit) (*7) (*1)
Selection (Nomal specification/expanded specification) of specifica-
J-3. SPEC
tions of burnout & saturation current (*1)
K. GUARD
Setting and cancellation of set value protection (write protect) (*9)
L-1. HisZERO
Display of zero calibration data for users
L-2. HisSPAN
Display of span calibration data for users
L-3. HisCLEAR Clearing of zero/span calibration data (*1)
L-4. HisAMP
L-5. HisCELL
Display of min/max of cell temperature history information
Description
Page
44
45
46
46
47
47
48
49
50
51
51
52
53
53
54
55
56
57
57
57
58
58
59
60
61
61
62
62
63
64
65
65
66
67
68
68
68
69
69
TN5FCXA2V5h-E

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents