Piping Of Remote Seal(S) Type Transmitters (Fkd, Fkm, Fkb) - Fuji Electric FCX-AII-V5 series Instructions Manual And Service Instructions

Hide thumbs Also See for FCX-AII-V5 series:
Table of Contents

Advertisement

3.2.5 Remote seal(s) type transmitter (FKB, FKD and FKM)
(1) Remote seal type differential pressure transmitter (FKD)
Check of high/low pressure sides of transmitter
The "High" Pressure side is indicated by "H" and the "Low" pressure side by "L" on the cell
neck. High pressure side is always with a
capillary or a rigid seal (direct mounting)
allowing a remote seal connection.
tank.
Be careful to a potential leak who can effect the
measure.
CAUTION
Standard dimension of the diaphragme seal are :
Flange size
DN80 / 3"
DN100 / 4"
cycles using the tightening torque corresponding to the screw used and according to the
TN5FCXA2V5h-E
The internal diameter must be greater or equal to the diaphragm seal to
not press it and effect the measure.
Be careful to a potential leak who can effect the measure.
H
Transmitter flange
Ø diaphragm seal (mm)
SS : 73
Special material : 89
SS : 96
Special material : 89
L
Gasket
Process side
flange
27