Product Identification; Nameplate; Additional Warning Plate - ABB ProcessMaster FEM630 Operating Instructions Manual

Electromagnetic flowmeter
Hide thumbs Also See for ProcessMaster FEM630:
Table of Contents

Advertisement

FE M63 0 | E L EC TR OM AG N E T I C FLOWM E T E R | O I/F E M6 3 0-EN RE V. A
3

Product identification

Name plate
Note
The name plates displayed are examples. The device
identification plates affixed to the device can differ from this
representation.
FEM631
1
Type designation
2
CE mark (pending)
3
Power supply
4
IP rating in accordance with EN 60529
5
Tamb = maximum permissible ambient temperature
6
Nominal diameter
7
Process connection / pressure rating
8
Calibration value QmaxDN
9
Excitation frequency
j
Liner material
k
Electrode material / Supplementary information:
EE = grounding electrodes
l
Tmed = maximum permissible measuring medium temperature
m
Label indicating whether the pressure equipment is subject to
the Pressure Equipment Directive.
n
Calibration value Sz (zero point), Ss (range)
o
'Follow operating instruction' symbol
p
'Caution hot surface' symbol
q
Ex marking in accordance with ATEX / IECEx (example)
(pending)
r
Manufacturer address
s
Year of manufacture
t
Software version
u
Model number (for more detailed information about the
technical design, refer to the data sheet or the order
confirmation)
v
Order number / Serial number for identification by the
manufacturer
Figure 4 Name plate (example)
Note
Devices with 3A approval SIL are labeled with an additional
plate.
Marking in accordance with Pressure Equipment
Directive 2014/68/EU (pending)
Information on the relevant fluid group
(Figure 4, Position
m
):
• PED: Fluid 1, Gas
Fluid group 1 = hazardous fluids, liquid, gaseous. (PED =
PressureEquipmentDirective).
• SEP
If the pressure equipment is not in the scope of the
Pressure Equipment Directive, it is classified in
accordance with SEP = Sound Engineering Practice
('sound engineering practice') in accordance with Art. 4
para. 3 of the Pressure Equipment Directive.
If there is no such information at all, there is no compliance
with the requirements of the Pressure Equipment Directive.
Water supplies and connected equipment accessories are
classed as an exception in accordance with guideline 1/16 of
Art. 1 Para. 3.2 of the Pressure Equipment Directive.

Additional warning plate

Devices which are approved for use in potentially explosive
atmospheres have an additional warning plate.
Warnung!
Gefahr durch elektrostatische Entladung
Warning!
1
Danger by electrostatic unloading
AVERTISSEMENT!
Risque de d charge électrostatique
Warnung!
Nicht öffnen, wenn eine explosionsfähige Athmosphäre vorhanden ist.
2
Warning!
DO NOT OPEN WHEN AN EXLPOSIVE ATMOSPHERE IS PRESENT
AVERTISSEMENT!
Ne pas ouvrir en presence d'une atmosphere explosive
Achtung:
Heisse Oberfläche
Warning:
3
Hot Surface
Attention:
Surface tres chaude
1
WARNING - Danger due to electrostatic discharge.
2
WARNING - Do not open if an explosive atmosphere is present.
3
WARNING - Hot surface.
4
Thread for cable glands
Figure 5 Additional warning plate
11
4
G12174

Hide quick links:

Advertisement

Table of Contents
loading