114
F EM63 0 | E L EC TR OM AG N E T I C FLOWM E T E R | O I/F E M6 3 0-EN RE V. A
9
. . .Diagnosis / error messages
. . .Overview
Error no . / Range
Error text
ADC RX210 com.
F090.035 /
error.
Electronics
Call service.
FEB communication
F088.012 /
error.
electronics
EMC disturbance.
Call Service.
Curr.Out 31 / 32 com
error.
F086.018 /
Defective Board. EMC
Electronics
disturbance. Call
Service.
NV data defect.
F084.010 /
Data storage
electronics
irreparable. Call
Service.
Incompatible
Frontend Board.
F082.013 /
Frontend not fit to
Electronics
Motherboard. Call
Service.
MB voltages outside
range.
F081.025 /
Defective
electronics
Motherboard HW.
Call Service.
Flowrate to zero.
C078.003 / Config.
Check digital in
terminals.
All totalizer stop.
C076.005 / Config.
Check digital in
terminals.
Totalizer reset.
C074.006 / Config.
Reset of one or more
Totalizers.
Simulation is on.
Simulated values.
C072.002 / Config.
Switch off Simulation
Mode.
An alarm is
simulated.
C070.026 / Config.
Switch off alarm
simulation.
Current output
Digital output
4 mA (0 % flow)
Current value - no
change.
Current value - no
Current value - no
change.
change.
Current value - no
Current value - no
change.
change.
Current value - no
Current value - no
change.
change.
Current value - no
Current value - no
change.
change.
Pulse output
LCD display
0 Hz
0 %
0 Hz
0 %
Current value - no
Current value -
change.
no change.
0 Hz
0 %
0 Hz
0 %
0 Hz
0 %
0 Hz
0 %
Current value - no
Current value -
change.
no change.
Current value - no
Current value -
change.
no change.
Current value - no
Current value -
change.
no change.
Current value - no
Current value -
change.
no change.
Error maskable?
No
No
No
No
No
No
Menu '...Group
Masking'.
Menu '...Group
Masking'.

Hide quick links: