130
F EM63 0 | E L EC TR OM AG N E T I C FLOWM E T E R | O I/F E M6 3 0-EN RE V. A
13

Specification

Note
The device data sheet is available in the ABB download area
at www.abb.com/flow.

Permitted pipe vibration

In accordance with EN 60068-2-6
Valid for sensors in remote mount and integral mount
design.
• Maximum deflection: 0.0006" (0.15 mm) in the frequency
range of 10 to 58 Hz
• Maximum acceleration: 2 g in the frequency range of 58 to
150 Hz
ProcessMaster – Temperature data
The temperature range offered by the device is dependent
on a number of different factors.
These factors include the measuring medium temperature
T
, the ambient temperature T
medium
P
, liner material and the approval for explosion
medium
protection.
Storage temperature range
−40 to 158 °F (−40 to 70 °C)
, operating pressure