ABB ProcessMaster FEM630 Operating Instructions Manual page 27

Electromagnetic flowmeter
Hide thumbs Also See for ProcessMaster FEM630:
Table of Contents

Advertisement

FE M63 0 | E L EC TR OM AG N E T I C FLOWM E T E R | O I/F E M6 3 0-EN RE V. A
5
. . .Installation
. . .Installing the plug-in cards
1
Cover
2
LCD indicator
3
Slot OC1
4
Slot OC2
5
Plug-in cards
Figure 27 Installation of plug-in cards (example, single-compartment housing)
WARNING
Risk of injury due to live parts!
When the housing is open, contact protection is not
provided and EMC protection is limited.
• Before opening the housing, switch off the power
supply.
NOTICE
Damage to components!
The electronic components of the printed circuit board
can be damaged by static electricity (observe ESD
guidelines).
• Make sure that the static electricity in your body is
discharged before touching electronic components.
1
Switch off the power supply.
2
Unscrew / remove the cover.
3
Remove the LCD indicator. Ensure that the cable harness
is not damaged.
Insert the LCD indicator into the bracket
4 (only for single-compartment housings)
5
Remove frontend board (only in integral mount design
and dual-compartment housing). Ensure that the cable
harness is not damaged.
6
Insert the plug-in card in the corresponding slot and
engage. Ensure that the contacts are aligned correctly.
7
Attach the frontend board, insert the LCD indicator and
screw on / replace the cover.
8
Connect outputs V1 / V2 and V3 / V4 in accordance with
Electrical connections on page 29.
9
After powering up the power supply, configure the plug-
in card functions.
27

Hide quick links:

Advertisement

Table of Contents
loading