6
FEP630, FEH630 ELECTROMAGNETIC FLOWMETER | CI/FEP630/FEH630-EN REV. D
... 1 Safety
Manufacturer's address
ABB Automation Products GmbH
Measurement & Analytics
Dransfelder Str. 2
37079 Goettingen
Germany
Tel: +49 551 905-0
Fax: +49 551 905-777
Email: vertrieb.messtechnik-produkte@de.abb.com
ABB Automation Products GmbH
Measurement & Analytics
Dransfelder Str. 2
37079 Goettingen
Germany
Tel: +49 551 905-0
Fax: +49 551 905-777
Email: vertrieb.messtechnik-produkte@de.abb.com
ABB Inc.
Measurement & Analytics
125 E. County Line Road
Warminster, PA 18974
USA
Tel: +1 215 674 6000
Fax: +1 215 674 7183
ABB Engineering (Shanghai) Ltd.
Measurement & Analytics
No. 4528, Kangxin Highway, Pudong New District
Shanghai, 201319,
P.R. China
Tel: +86(0) 21 6105 6666
Fax: +86(0) 21 6105 6677
Email: china.instrumentation@cn.abb.com
Customer service center
Tel: +49 180 5 222 580
Email: automation.service@de.abb.com
2 Product identification
Name plate
Note
The name plates displayed are examples. The device
identification plates affixed to the device can differ from this
representation.
Note
Products that are marked with the adjacent symbol
may not be disposed of as unsorted municipal waste
(domestic waste).
They should be disposed of through separate
collection of electric and electronic devices.
1 Type designation
2 CE mark
3 Power supply
4 IP rating in accordance with
EN 60529
5 T
= maximum permissible
amb
ambient temperature
6 Nominal diameter
7 Process connection / pressure
rating
8 Calibration value Q
DN
max
9 Excitation frequency
0 Liner material
k Electrode material /
Supplementary information:
EE = grounding electrodes,
TFE = partial filling electrode
l T
= maximum permissible
med
measuring medium
temperature
m Label indicating whether the
pressure equipment is subject
to the Pressure Equipment
Directive.
Figure 1: Name plate (example)
Note
Devices with 3A approval SIL are labeled with an additional plate.
n Calibration value Sz (zero point), Ss
(range)
o 'Follow operating instruction'
symbol
p 'Caution hot surface' symbol
q Ex marking in accordance with
ATEX / IECEx (example)
r Manufacturer address
s Year of manufacture
t Software version
u Model number (for more detailed
information about the technical
design, refer to the data sheet or
the order confirmation)
v Order number / Serial number for
identification by the manufacturer
Need help?
Do you have a question about the ProcessMaster FEP630 and is the answer not in the manual?