ABB ProcessMaster FEM630 Operating Instructions Manual page 99

Electromagnetic flowmeter
Hide thumbs Also See for ProcessMaster FEM630:
Table of Contents

Advertisement

FE M63 0 | E L EC TR OM AG N E T I C FLOWM E T E R | O I/F E M6 3 0-EN RE V. A
8
. . .Operation
. . .Parameter descriptions
Diagnostics / . . .Diagnosis Control / . . .Diagnosis Conductiv*
Conductivity On/Off
Conductivity[µS/cm]
Adj. Cond. Value
Cond. Iout Min Value
Cond. Iout Max Value
Cond.Min Alarm Value
Cond.Max Alarm Value
Elec. Imp. E1-GND
Elec. Imp. E2-GND
Diagnostics / . . .Diagnosis Control / . . .Diagnosis SIL**
SIL On/Off
*
The menu is only available if the Expert Diagnosis function is activated. See also the 'Device Setup\...Transmitter\...Feature Settings' menu.
**
Menu only available if SIL diagnostic function is activated. See also the 'Device Setup\...Transmitter\...Feature Settings' menu.
Activate the conductivity diagnostic function.
Default setting: Off
Note
Conductivity diagnostic can be used in the nominal diameter range of 3/8" to 12" (DN 10 to 300).
For additional information, see Extended diagnostic functions on page 118.
Indicator of the measured conductivity in μS/cm
Conductivity must be set in accordance with the conditions on-site.
Measure the conductivity using a conductivity meter on-site and enter the measured value here.
Limits: 5 to 20000 μS/cm
The conductivity value is available as a 4 to 20 mA-output (option card).
Set the 4 mA and 20 mA value which correspond to the upper and lower range of the conductivity value.
Set the alarm for minimum and maximum conductivity. In the case of down-scale, an alarm is triggered.
Limits: 5 to 20000 μS/cm
Electrical impedance E1-GND.
Current impedance between electrode E1 and GND (ground potential).
Electrical impedance E2-GND.
Current impedance between electrode E2 and GND (ground potential).
For information purposes only.
SIL devices are delivered ex works as SIL devices. There is no special SIL mode to activate
99