Inserting And Specifying Motors That Are Missing From The Motor List - Siemens SINAMICS S120 Getting Started

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Result
The motor is inserted and specified. If you have selected a motor without encoder, add an
encoder and an encoder evaluation in the next step.
5.4.5.3

Inserting and specifying motors that are missing from the motor list

If you want to insert, specify and manage motors in your device configuration, which are not
contained in the motor list, you can enter the most important motor data, such as the rating
plate values of the motor, manually in the Inspector window.
Note
The mandatory fields for entering motor data manually are shown in pink in the appropriate
screen forms. If appropriate values are not entered in these fields, then the device
configuration cannot be completed.
Procedure
Proceed as follows to insert and specify motors in your device configuration:
1. Open the "Motors" item in the hardware catalog and then the subitem "Motor data input".
The motors are presorted according to motor type. A range of induction motors,
synchronous motors and reluctance motors are available for a general selection.
2. Select the unspecified motor in the device overview.
3. Drag the unspecified motor to the lower area of the Motor Module.
4. Click the unspecified motor in the device view.
5. Open the Inspector window if it has still not been opened or displayed.
6. In the Inspector window, select the "Motor details" menu.
The "Motor details" input screen form is divided into the sections:
– Rating plate values
– Motor brake (see Chapter"Adding a standard motor")
– Optional motor data (can also be activated)
– Equivalent circuit diagram data (can also be activated)
7. If you also want to acquire subareas "Optional motor data" and "Equivalent circuit
diagram data", in the "Rated plate values" screen form, activate options "Activate the
display of the optional motor data" and "Activate the display of the optional equivalent
circuit diagram data".
Getting Started, 12/2018, 6SL3097-5AG30-0BP0
5.4 Creating a project offline in Startdrive