Commissioning
5.4 Creating a project offline in Startdrive
Setting the drive object type in the Motor Modules or Power Modules list
1. If the device configuration is not active in your Startdrive project, call it via the project tree.
2. Select the desired drive axis in the device configuration.
3. Open the Inspector window if it has still not been opened or displayed.
4. In the Inspector window, select entry "Motor Module - Selection - xxx" or "Power Module -
A list of relevant modules opens:
Figure 5-21
5. Select the required type (High dynamic "SERVO" or Universal "VECTOR") in the
"Selected drive object type" drop-down list.
A confirmation prompt appears as to whether you really want to change the drive object
type.
6. Click "Yes" to confirm the prompt.
The Motor/Power Module drop-down list is now refreshed. Only Motor/Power Modules of
the selected type are now available for selection.
7. Save the changes in the project.
Setting the drive object type in the project information
1. If the device configuration is not active in your Startdrive project, call it via the project tree.
2. Select the desired drive axis in the device configuration.
3. Open the Inspector window if it has still not been opened or displayed.
86
Selection - xxx".
Changing the drive object type in the module list
Getting Started, 12/2018, 6SL3097-5AG30-0BP0