3. Drag a non-specified Motor Module into the device view, into the light gray area of the
existing Motor Module.
Figure 5-20
Then also specify the Motor Module connected in parallel (refer to Chapter "Inserting and
specifying a Motor Module (Page 78)").
Additional Motor Modules can be connected in parallel in the same manner.
Result
The Motor Module connected in parallel is inserted and specified. The white area turns gray.
The Motor Modules are linked with one another via interfaces X401 and X400.
Note
If required, you can activate or deactivate a parallel connection for individual Motor Modules
via the Inspector window (Motor Module_xxx / drop-down list "Component activation").
For deactivation, the respective Motor Module must be disconnected from the network (using
a contactor, for example). Motor supply cables must be opened.
5.4.4.5

Changing the drive object type

The drive object type can be changed in the Motor Modules drop-down list or in the Power
Modules drop-down list as well as in the project information of the drive axis.
Precondition
A Power Module or a Motor Module is created and, if required, specified in Startdrive in the
device configuration.
Getting Started, 12/2018, 6SL3097-5AG30-0BP0
Connecting Motor Modules in parallel
5.4 Creating a project offline in Startdrive
Commissioning