Siemens SINAMICS S120 Getting Started page 112

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Commissioning
5.7 Alternatively: Creating a project with a device configuration derived from the hardware
If you want to set another motor control, proceed as follows:
1. Activate the option of the required drive object type in the dialog header.
– Universal (vector) = VECTOR drive object type
– High dynamic (servo) = SERVO drive object type
– Can be selected = drive object type for each detected drive axis in the table can be
2. If you have selected the "Can be selected" option, select the required drive object type
separately for each drive axis in the column of the same name via a drop-down list.
Configuring the topology
If all components found in the actual topology have been assigned, no further adaptations
must be made in the
"Detection of the device configuration" dialog. The "Create" button can then be selected.
If the "Create" button cannot be selected (i.e. is grayed out), the topology of the components
still has to be adapted:
Changing the assignment of components
1. Select a component in the list that you want to assign to a different main component.
2. Move this component to the desired main component using drag & drop.
Assigning a non-assigned component to a main component
1. Select a component which has not yet been assigned in the "Non-assignable
components" folder.
2. Call the "Assign to / Main component xy" shortcut menu.
"Main component xy" stands for all of the main components used in the list.
The component is assigned to the desired main component in the list.
Deleting a component
1. Select the components which are to be deleted.
2. Call the "Delete" shortcut menu.
The component is deleted.
Note
All components in the "Non-assignable components" folder prevent the creation of this read-
out actual topology of the drive unit in the device configuration.
If individual components which have not yet been assigned cannot be assigned to a main
component, delete the corresponding list entries in the "Non-assignable components" folder,
in order that the remaining components can be adopted in the device configuration.