6.4

CANopen operating modes

The inverter has the following CANopen operating modes
CANopen operating mode
Active
operating mode
Velocity Mode
Manufacturer-
specific operating
mode 1
Manufacturer-
specific operating
mode 2
Manufacturer-
specific operating
mode 3
Manufacturer-
specific operating
mode 4
Manufacturer-
specific operating
mode 5
Manufacturer-
specific operating
mode 6
Manufacturer-
specific operating
mode 7
Manufacturer-
specific operating
mode 8
Manufacturer-
specific operating
mode 10
Manufacturer-
specific operating
mode 11
Profile Velocity
Mode
Manufacturer-
specific operating
mode 12
Profile Torque
Mode
Fieldbuses
Function Manual, 01/2016, FW V4.7 SP6, A5E34229197B AC
SINAMICS
Setting in
6502 h:
Open-loop/closed-loop con-
6060 h:
Display
trol mode
the acti-
ve opera-
Value
ting
mode in
2
Bit1
U/f control with linear chara-
cteristic
-1
Bit16
U/f control with linear chara-
cteristic and FCC
-2
Bit17
U/f control with parabolic
characteristic
-3
Bit18
U/f control with paramete-
rizable characteristic
-4
Bit19
U/f control with linear chara-
cteristic and ECO
-5
Bit20
U/f control for drive requiring
a precise frequency (e.g.
textiles)
-6
Bit21
U/f control for drive requiring
a precise frequency and
FCC
-7
Bit22
U/f control with parabolic
characteristic and ECO
-15
Bit23
Operation with braking resis-
tor
-19
Bit25
U/f control with independent
voltage setpoint
-20
Bit26
Speed control (without en-
coder)
3
Bit2
Speed control (with encoder)
-22
Bit27
Torque control (without en-
coder)
4
Bit3
Closed-loop torque control
(with encoder)
Communication over CANopen
6.4 CANopen operating modes
Control Unit /
inverter
x
x
x
x
x
x
x
x
x
X
x
x
x
x
X
x
X
x
x
x
x
x
x
x
x
x
x
x
x
x
Value
in
p1300
0
1
2
3
4
5
6
7
15
19
20
21
22
23
179