Siemens SINAMICS G110M Function Manual page 129

Fieldbuses
Hide thumbs Also See for SINAMICS G110M:
Table of Contents

Advertisement

Modbus
Description
register
number
40499
PRM ERROR code
Technology controller
40500
Technology controller enable
40501
Technology controller MOP
Technology controller adjustment
40510
Time constant for actual-value filters of
the technology controller
40511
Scaling factor for actual value of the
technology controller
40512
Proportional amplification of the tech-
nology controller
40513
Integral time of the technology control-
ler
40514
Time constant D-component of the
technology controller
40515
Max. limit of technology controller
40516
Min. limit technology controller
PID diagnostics
40520
Effective setpoint acc. to internal tech-
nology controller MOP ramp-function
generator
40521
Actual value of technology controller
after filter
40522
Output signal technology controller
Acyclic communication
40601
DS47 Control
40602
DS47 header
40603
DS47 data 1
...
...
40722
DS47 data 120
Fieldbuses
Function Manual, 01/2016, FW V4.7 SP6, A5E34229197B AC
Modb
Unit
Scaling
us
factor
ac-
cess
R
--
1
R/W
--
1
R/W
%
100
R/W
--
100
R/W
%
100
R/W
--
1000
R/W
s
1
R/W
--
1
R/W
%
100
R/W
%
100
R
%
100
R
%
100
R
%
100
R/W
--
--
R/W
--
--
R/W
--
--
R/W
--
--
Communication via RS485
5.4 Communication using Modbus RTU
ON/OFF text
Data / parameter
or Value range
0 ... 255
--
0 ... 1
p2200, r2349.0
-200.0 ... 200.0
p2240
0.00 ... 60.0
p2265
0.00 ... 500.00
p2269
0.000 ... 65.000
p2280
0 ... 60
p2285
0 ... 60
p2274
-200.0 ... 200.0
p2291
-200.0 ... 200.0
p2292
-100.0 ... 100.0
r2250
-100.0 ... 100.0
r2266
-100.0 ... 100.0
r2294
--
--
--
--
--
--
--
--
129