8. Select your subnet.
9. Using the hardware catalog, first insert the inverter using drag & drop.
10.Insert the communication telegram.
11.Open the properties window of the inverter and enter a unique and descriptive device
name for the inverter.
Using the device name, the PROFINET controller assigns the IP address when starting
up.
12.You will also find the proposed IP address in this screen form. If required, you can
change the IP address via "Properties".
13.Save your hardware configuration with "Save and compile" (
14.Load the configuration into the control unit via the
Fieldbuses
Function Manual, 01/2016, FW V4.7 SP6, A5E34229197B AC
A.1 Communication with STEP7
).
button.
Appendix
219