Siemens SINAMICS G110M Function Manual page 94

Fieldbuses
Hide thumbs Also See for SINAMICS G110M:
Table of Contents

Advertisement

Communication via EtherNet/IP
4.5 Supported objects
TCP/IP Interface Object, Instance Number: F5 hex
Supported services
Class
• Get Attribute all
• Get Attribute single
Table 4- 21
No.
1
2
3
Table 4- 22
No.
1
2
3
4
5
6
10
11
94
Class Attribute
Service
Type
Name
get
UINT16
Revision
get
UINT16
Max Instance
get
UINT16
Num of Instances
Instance Attribute
Service
Type
Name
get
UNIT32
Status
get
UNIT32
Configuration Capa-
bility
get, set
UNIT32
Configuration Con-
trol
get, set
UNIT16
Path Size (in
WORDs)
UNIT8
Path
get, set
STRING
Interface Configura-
tion
UNIT32
get, set
UNIT16
Host Name
STRING
get, set
UNIT8
Select ACD
get, set
UNIT8
Last Conflict Detec-
ted
UNIT8
UNIT8
Instance
• Get Attribute all
• Get Attribute single
• Set Attribute single
Value/explanation
Fixed value: 1 hex
1: Configuration acknowledged, by DHCP or
saved values
Fixed value: 94 hex
4 hex: DHCP supported,
10 hex: Configuration can be adjusted,
80 hex: ACD-capable
1 hex: Saved values
3 hex: DHCP
Fixed value: 2 hex
20 hex,
F6 hex,
24 hex,
05 hex, where 5 hex is the number of instances
of F6 hex (four physical ports plus one internal
port).
r61000 Name of Station
r61001 IP address
Host Name Length
local OM flash:
0: Disabled,
1: Enabled
local OM flash ACD Activity
local OM flash Remote MAC
local OM flash ARP PDU
Function Manual, 01/2016, FW V4.7 SP6, A5E34229197B AC
Fieldbuses

Advertisement

Table of Contents
loading

Table of Contents