Danfoss VLT AutomationDrive FC 300 Design Manual page 66

0.25-75 kw
Hide thumbs Also See for VLT AutomationDrive FC 300:
Table of Contents

Advertisement

FC 300 Selection
High/Normal Load
Typical Shaft output [kW]
Enclosure IP20
Enclosure IP21
Enclosure IP55, IP66
Output current
Continuous (3x380-440 V) [A]
4
4
Intermittent (60 s overload)
(3x380-440 V) [A]
Continuous (3x441-500 V) [A]
Intermittent (60 s overload)
(3x441-500 V) [A]
Continuous kVA (400 V AC) [kVA]
Continuous kVA (460 V AC) [kVA]
Max. input current
Continuous (3x380-440 V) [A]
Intermittent (60 s overload)
(3x380-440 V) [A]
Continuous (3x441-500 V) [A]
Intermittent (60 s overload)
(3x441-500 V) [A]
Additional specifications
IP20 max. cable cross-section
(mains and motor)
IP20 max. cable cross-section
(brake and load sharing)
IP21, IP55, IP66 max. cable cross-
section
5)
(mains, motor) [mm
2)
(AWG)]
IP21, IP55, IP66 max. cable cross-
5)
section
(brake, load sharing)
[mm
2
(AWG)]
2)
Max cable size with mains
disconnect [mm
Estimated power loss
at rated max. load [W]
Weight,
enclosure IP21, IP55, IP66 [kg]
4)
Efficiency
Table 4.6 Mains Supply 3x380-500 V AC (FC 302), 3x380-480 V AC (FC 301)
For fuse ratings, see 7.2.1 Fuses
1) High overload = 160% torque during 60 s. Normal overload = 110% torque during 60 s.
2) American Wire Gauge.
3) Measured using 5 m screened motor cables at rated load and rated frequency.
4) The typical power loss is at nominal load conditions and expected to be within
cable conditions).
Values are based on a typical motor efficiency (eff2/eff3 border line). Motors with lower efficiency will also add to the power loss in the
frequency converter and opposite.
If the switching frequency is increased compared to the default setting, the power losses may rise significantly.
64
RSPSupply - 1-888-532-2706 - www.RSPSupply.com
http://www.RSPSupply.com/p-21462-Danfoss-131B8966-VLT-Automation-VT-Drive-VFD-FC301-230V-5-HP.aspx
P30K
1)
HO
30
B4
C1
C1
61
91.5
52
78
42.3
55
82.5
47
70.5
5)
35 (2)
5)
35 (2)
2
50 (1)
50 (1)
2
2)
(AWG)]
570
4)
45
0.98
MG33BE02 - VLT
®
VLT
AutomationDrive FC 300 Design Guide, 0.25-75 kW
P37K
NO
HO
NO
37
37
45
C3
C1
C1
73
73
90
80.3
110
99
65
65
80
71.5
97.5
88
50.6
50.6
62.4
51.8
63.7
66
66
82
72.6
99
90.2
59
59
73
64.9
88.5
80.3
50 (1)
50 (1)
50 (1)
50 (1)
50, 35, 35
(1, 2, 2)
698
697
843
45
0.98
®
is a registered Danfoss trademark
P45K
P55K
HO
NO
HO
NO
45
55
55
75
C3
C4
C1
C2
C1
C2
90
106
106
147
135
117
159
162
80
105
105
130
120
116
158
143
62.4
73.4
73.4
102
83.7
104
82
96
96
133
123
106
144
146
73
95
95
118
110
105
143
130
50 (1)
150 (300 MCM)
50 (1)
95 (4/0)
50 (1)
150 (300 MCM)
50 (1)
95 (3/0)
95, 70, 70
(3/0, 2/0, 2/0)
891
1083
1022
1384
45
65
0.98
0.98
± 15% (tolerence relates to variety in voltage and
P75K
HO
NO
75
90
C4
C2
C2
147
177
221
195
130
160
195
176
102
123
128
133
161
200
177
118
145
177
160
150 (300 MCM)
95 (4/0)
150 (300MCM)
95 (3/0)
185, 150, 120
(350 MCM, 300
MCM, 4/0)
1232
1474
65
0.99