FC 300 Selection
1)
High/Normal Load
Typical Shaft Output [kW]
Enclosure IP20
Enclosure IP21
Enclosure IP55, IP66
Output current
Continuous (3x200-240 V) [A]
Intermittent
(60 s overload)
(3x200-240 V) [A]
Continuous kVA (208 V AC) [kVA]
Max. input current
Continuous (3x200-240 V) [A]
Intermittent
(60 s overload)
(3x200-240 V) [A]
Additional specifications
5)
IP20 max. cable cross-section
(mains, brake, motor and load
sharing)
IP21, IP55, IP66 max. cable cross-
5)
2
section
(mains, motor) [mm
2)
(AWG)]
IP21, IP55, IP66 max. cable cross-
section
5)
(brake, load sharing)
2
2)
[mm
(AWG)]
Max cable size with mains
2
2)
disconnect [mm
(AWG)]
Estimated power loss
4)
at rated max. load [W]
Weight, enclosure IP21, IP55/IP66
[kg]
Efficiency
4)
Table 4.3 Mains Supply 3x200-240 V AC
For fuse ratings, see 7.2.1 Fuses
1) High overload = 160% torque during 60 s. Normal overload = 110% torque during 60 s.
2) American Wire Gauge.
3) Measured using 5 m screened motor cables at rated load and rated frequency.
4) The typical power loss is at nominal load conditions and expected to be within
cable conditions).
Values are based on a typical motor efficiency (eff2/eff3 border line). Motors with lower efficiency will also add to the power loss in the
frequency converter and opposite.
If the switching frequency is increased compared to the default setting, the power losses may rise significantly.
LCP and typical control card power consumptions are included. Further options and customer load may add up to 30 W to the losses.
(Though typical only 4 W extra for a fully loaded control card, or options for slot A or slot B, each).
Although measurements are made with state of the art equipment, some measurement inaccuracy must be allowed for (
5) The three values for the max. cable cross section are for single core, flexible wire and flexible wire with sleeve, respectively.
RSPSupply - 1-888-532-2706 - www.RSPSupply.com
http://www.RSPSupply.com/p-21462-Danfoss-131B8966-VLT-Automation-VT-Drive-VFD-FC301-230V-5-HP.aspx
®
VLT
AutomationDrive FC 300 Design Guide, 0.25-75 kW
P15K
P18K
HO
NO
HO
NO
15
18.5
18.5
22
B4
C3
C1
C1
C1
C1
59.4
74.8
74.8
88
89.1
82.3
112
96.8
21.4
26.9
26.9
31.7
54
68
68
80
81
74.8
102
88
35 (2)
50 (1)
50 (1)
50 (1)
50 (1)
50 (1)
50, 35, 35 (1, 2, 2)
624
737
740
845
45
45
0.96
0.97
®
MG33BE02 - VLT
is a registered Danfoss trademark
P22K
P30K
HO
NO
HO
NO
22
30
30
37
C3
C4
C1
C2
C1
C2
88
115
115
143
132
127
173
157
31.7
41.4
41.4
51.5
80
104
104
130
120
114
156
143
50 (1)
150 (300MCM)
50 (1)
150 (300MCM)
50 (1)
95 (3/0)
95, 70, 70
(3/0, 2/0, 2/0)
874
1140
1143
1353
45
65
0.97
0.97
± 15% (tolerence relates to variety in voltage and
P37K
HO
NO
37
45
C4
C2
C2
143
170
4
4
215
187
51.5
61.2
130
154
195
169
150 (300MCM)
150 (300MCM)
95 (3/0)
185, 150, 120
(350MCM,
300MCM, 4/0)
1400
1636
65
0.97
± 5%).
61