Syntax:
STP bpduFilter [enable|disable]
Parameters:
enable|disable: enable or disable BPDU Filtering for Edge ports
Default Setting:
Disable
Example:
Set edge port BPDU filtering
stp bpdufilter enable
NS3552-8P-2S:/>
STP BPDU Guard
Description:
Set or show edge port BPDU Guard.
Syntax:
STP bpduGuard [enable|disable]
Parameters:
enable|disable: enable or disable BPDU Guard for Edge ports
Default Setting:
Disable
Example:
Set edge port BPDU guard
stp bpduguard enable
NS3552-8P-2S:/>
STP Recovery
Description:
Set or show edge port error recovery timeout.
Syntax:
STP recovery [<timeout>]
Parameters:
<timeout>: Time before error-disabled ports are reenabled (30-86400 seconds, 0
disables)
(default: Show recovery timeout)
Default Setting:
Disable
Example:
Set STP recovery value in 30 sec.
stp recovery 30
NS3552-8P-2S:/>
STP Status
Description:
Show STP Bridge status.
Syntax:
STP Status [<msti>] [<port_list>]
Parameters:
<msti>
: STP bridge instance no (0-7, CIST=0, MSTI1=1, ...)