2.3.3
The table, starting below, lists complete technical specifications
for the Enhanced Vibrex 2000 Plus system.
Characteristic
Basic Specifications
Data storage capacity
Built-in test (BIT)
coverage
Date and time stamping
Log (data) files -
contents and formats
Compatible software
(ground based)
Basic Performance
Frequency range
Accuracy
Acquisition capability
Balance Measurements
Phase units
Phase resolution
Honeywell Confidential: Use or disclosure of information on this page is subject to the restrictions on the title page.
Enhanced Vibrex 2000 Plus
Specifications
Specifications
1 Mb
Memory check and calibration on power
up; user-initiated tests (with
check battery and sensor power
Yes
Balance jobs, log book, balance, spectrum,
fault log, all in ASCII format
Honeywell V2K Download and V2K Plot
programs
0 to 10,000 Hz
±.5dB, from 5 Hz to 500 Hz; ±1dB, from
500 Hz to 10,000 Hz
4 vibration and 2 tachometer (azimuth)
Hours and minutes
2 min or 1°
13841 Rev A
21
Chapter 2 – System Overview
NOTE: Errors are logged to a
printable fault log.
key)