Obtaining Balance Solutions - Honeywell Vibrex 2000 User Manual

Digital dynamic balancer / analyzer systems
Table of Contents

Advertisement

5.4.3
After the balance reading displays and the user presses the
START
change solution (in grams) at a specific clock angle.
The illustration below shows an example of a typical Vibrex
unit's Solution screen.
► VIEW PROP MEASURMENT
RUN
ADD [ 5.2
► AT [ 1:29]
?
FOLLOW INSTRUCTIONS
next run, push START
5.4.3.1
In applying balance solutions, use the following guidelines:
There may be some cases where the user cannot physically
place the weight at a specified location, or the user must add
balance weights different from those specified. To account
for these variations, the user must input the weight and clock
angle of the actual adjustment into the Vibrex unit.
If the specified weight differs from that added to the
propeller or the angle placement is different than that
Honeywell Confidential: Use or disclosure of information on this page is subject to the restrictions on the title page.

Obtaining Balance Solutions

key, the Vibrex unit presents its recommended weight
1 ADJUSTMENT
] GMS
(split)
SELECT FOR PROPELLER
PROTRACTOR INSTRUCTIONS
Application Guidelines
Chapter 5 – General Operation
13841 Rev A
117
SELECT TO VIEW
MEASUREMENT
AGAIN
SELECT TO ENTER
ACTUAL WEIGHT
ADDED (IN GRAMS)
SELECT TO
ENTER ACTUAL
ANGLE USED