Chapter 2 – System Overview
Characteristic
Date and time stamping
Log (data) files -
contents and formats
Compatible software
(ground based)
Basic Performance
Frequency range
Accuracy
Acquisition capability
Balance Measurements
Phase units
Phase resolution
Phase accuracy
Balance frequency range
Spectrum Analysis
Analysis ranges
(maximum frequencies)
Window type
FFT resolution
Signal Conversion (Vibration Inputs)
Honeywell Confidential: Use or disclosure of information on this page is subject to the restrictions on the title page.
Specifications (Continued)
Yes
Balance jobs, log book, balance, spectrum,
fault log, all in ASCII format
Honeywell V2K Download and V2K Plot
programs
0 to 10,000 Hz
±.5dB, from 5 Hz to 500 Hz; ±1dB, from
500 Hz to 10,000 Hz
2 vibration and 2 tachometer (azimuth)
Hours and minutes
2 min or 1°
±15°
120 to 30,000 RPM
1200, 3000, 6000, 12,000, 30,000, 60,000,
120,000, 300,000 and 600,000 RPM
Flat top
400 lines
13841 Rev A
18