9. Remove the CF card and insert it in the D410 slot.
10.Switch on the D410. The D410 starts with the downloaded project.
5.2.6

Downloading the project incl. sources and additional data

Overview
In the case of SIMOTION V4.1 SP2 and higher, it is possible to download additional data (e.g.
sources) to the target device when saving a project to the CF card or downloading to the
SIMOTION D410. These data are required for:
● Online object comparison (e.g. additional properties)
● Various detailed comparisons (e.g. ST source file comparison)
● Synchronization with online objects.
In order to be able to load a project's sources and additional data to the PG, this must be
specified in the project under "Options" > "Settings" > "Download" > "Store additional data on
the target device". Alternatively, this setting can also be made when the data is loaded to the
target device/target system.
You can, for example, perform a project comparison with the sources and additional data stored
on the CF card (see example below).
Project comparison (example)
You intend to perform servicing work on a commissioned system and have placed a project
on your PG/PC. This project is not consistent with the project on the SIMOTION D410 in the
system. In order to analyze the differences, perform an object comparison via "Start object
comparison".
You have the following options in terms of re-establishing consistency:
SIMOTION D410
Commissioning Manual, 04/2014
Note
The components' firmware is automatically updated, depending on the FW version on the
SINAMICS components and on the CompactFlash Card. During an FW update, please
take note of the messages and alarms in the SIMOTION SCOUT detail window. An FW
update on the SIMOTION D410 is indicated by the RDY LED flashing yellow, while on the
DRIVE-CLiQ components (TM, SMC, etc.) it is indicated by the RDY LED flashing red/
green.
● FW update running: RDY LED flashes slowly (0.5 Hz)
● FW update complete: RDY LED flashes quickly (2 Hz)
Go offline once all the FW updates are complete, then switch the 24 V supply for the
upgraded initialization components off/on.