Setting Up Communication For Symbolic Assignment; Message Frame Configuration - Siemens SIMOTION D410 Commissioning Manual

Hide thumbs Also See for SIMOTION D410:
Table of Contents

Advertisement

● With symbolic assignment , the addresses are determined automatically by the engineering
● in the absence of symbolic assignment, addresses must be determined manually; refer to
5.7.1

Setting up communication for symbolic assignment

You can set up communication for symbolic assignment using the following methods:
● via the SCOUT menu (in the menu, call "Project" > "Set up communication for symbolic
● at "Download project to target system"
● at "Save project and compile changes"
When you set up communication, the message frames, BICO interconnections, and addresses
are set up for the entire project.
See also
Message frame configuration (Page 121)
5.7.2

Message frame configuration

Requirement
You have configured the drive unit.
On the basis of this configuration, one or more of the following actions should be performed:
● The automatic PROFIdrive telegram setting for a drive object should be activated/
● The automatic telegram extension for a drive object should be activated/deactivated
● The automatic address adaptation for a drive object should be activated/deactivated
● PROFIdrive telegrams should be configured for drive objects
● The addresses should be set up
● Telegrams should be extended manually
Procedure
Proceed as follows:
In the project navigator, open the "Communication" > "Telegram configuration" entry under
"SINAMICS_Integrated."
The "SINAMICS Integrated - Telegram Configuration" dialog box is displayed with the
PROFIdrive PZD telegrams tab.
SIMOTION D410
Commissioning Manual, 04/2014
system; refer to section Setting up communication for symbolic assignment (Page 121)
section Message frame configuration (Page 121)
assignment")
deactivated
Commissioning (software)
5.7 Setting up addresses and message frames