5.2 Configuring the system in offline mode
3. To load the project, perform "Download project to target system".
4. To save the parameter calculations of the drive in the project, perform "Target device" >
Drive programming and commissioning is completed. You can now test the drive using the
drive control panel.
Note
Online access to SINAMICS Integrated is not possible if HW Config is not loaded at the time
you initially connect to the target system.
Download the data to HW Config in order to enable online access to SINAMICS Integrated.
During the "Download to target system" process, SIMOTION SCOUT automatically attempts
to establish an online connection to SINAMICS Integrated.
5.2.5

Loading a project created offline to the CompactFlash Card

Procedure
You can use a card reader to write the entire project to the CompactFlash Card, even in offline
mode. In SIMOTION SCOUT, you can call the "Download to the file system" function in the
context menu of the SIMOTION device.
1. Save and compile the project.
2. Switch off the SIMOTION D410.
3. Remove the CompactFlash Card and insert it in a card adapter. The card adapter must be
4. In the SCOUT project, select the SIMOTION D410 device that you want to download to the
5. Click "Download to the file system" in the context menu. A dialog box opens.
6. In the "Download to the file system" dialog, select the "Save normal" option and click the
7. Select the target drive.
8. Confirm your entries with "OK". The data will be written to the CompactFlash Card.
90
The data must also be saved on the CompactFlash Card to ensure that the project is
retained in the event of a power failure. The following options are available:
– Perform the "Copy RAM to ROM..." function manually on the SIMOTION D410 and the
drive (SINAMICS Integrated).
– In the "Download to Target System" dialog box, select the option "After loading, copy
RAM to ROM". You can change the default setting for this dialog box in "Options" >
"Settings" > "Download".
"Load CPU / drive unit to PG" for the drive.