5.16 Deleting data

See also
Properties of the user memories (Page 42)
5.16
Deleting data
5.16.1

Overview of data deletion

You can define the scope of data to be deleted from SIMOTION D410 memory described in
the "user memory concept". That is, you can choose to delete all data or only specific parts.
You have the following options of deleting data from SIMOTION D410:
● Resetting the memory of SIMOTION D410 (Page 152)
● Deleting user data from the CompactFlash Card (Page 155)
● Restoring the default settings of SINAMICS Integrated (Page 156)
● Restoring the default settings of SIMOTION D410 (Page 156)
● Deleting/restoring non-volatile SIMOTION data (Page 209).
5.16.2

Resetting the memory of SIMOTION D410

Introduction
A memory reset deletes all data from RAM on the SIMOTION D410 and non-volatile
SIMOTION data in the FRAM, with the exception of the communication configuration (baud
rates, network addresses, etc.). The data on the CF card is retained during the memory reset.
Reset the memory on SIMOTION D410 if
● If you want to undo changes made to user data (programs, configuration data, parameter
● The RUN/STOP LED is flashing (slowly flashing yellow) to indicate that the
● If the non-volatile SIMOTION data with the project on the CF card do not match and an
You can reset memory either in offline mode using the DIL switch of SIMOTION D410, or in
online mode using SIMOTION SCOUT.
152
assignments) which you have not backed up by means of the "Copy RAM to ROM"
command.
SIMOTION D410 is requesting a memory reset.
error occurs (diagnostic buffer entry).