Deleting User Data From The Compactflash Card - Siemens SIMOTION D410 Commissioning Manual

Hide thumbs Also See for SIMOTION D410:
Table of Contents

Advertisement

NOTICE
Unintentional restoration of the default settings instead of memory reset
Please note that, during startup, the MRES setting will cause the default settings to be
restored. For details, see Section Restoring the default settings of SIMOTION D410
(Page 156).
Make sure you do not accidentally switch the power supply OFF/ON in the MRES selector
setting, as this restores the default settings instead of performing the desired memory reset.
5.16.3

Deleting user data from the CompactFlash Card

Overview
Deletion of the user data from the CompactFlash Card is necessary, for instance, if you wish
to load another (new) project to the CompactFlash Card and therefore find it necessary to
delete the existing user data for an "old project" (e.g. unit data sets) from the CompactFlash
Card.
You can delete the user data using SIMOTION SCOUT. SIMOTION D410 must be operating
in online mode. This deletes the following data:
● User data from the "volatile data" area
● Non-volatile data, with the exception of IP and DP parameters
● User data on the CompactFlash Card (user folders), including the SINAMICS configuration
You can still go online to SIMOTION D410 at your programming device / PC. All licenses on
the CompactFlash Card are retained.
Deleting user data
1. Open the project you want to edit in SIMOTION SCOUT.
2. Go online to SIMOTION D410.
3. Select SIMOTION D410 in the Project Navigator, and then select the "Delete user data on
4. Confirm the "Delete user data from card" message with "OK".
SIMOTION D410
Commissioning Manual, 04/2014
data
card" option from the "Target system" menu.
The user data are deleted. SINAMICS Integrated goes into offline mode.
Commissioning (software)
5.16 Deleting data
155

Hide quick links:

Advertisement

Table of Contents