Commissioning (hardware)

3.1

Prerequisites for commissioning

Prerequisites
Prerequisites for commissioning the SIMOTION D410:
● You have completed installation and the wiring of your system with SIMOTION D410.
● A programming device / PC is available.
Connecting a programming device / PC to SIMOTION D410
You can interconnect the programming device / PC:
● With the PROFIBUS interface of SIMOTION D410 DP (X21 connector) using a connecting
● With the PROFINET interface of SIMOTION D410 PN (X200 or X201 connector) using a
System requirements
System requirements for hardware commissioning:
● The programming device must be equipped with a PROFIBUS or Ethernet adapter.
● The programming device / PC must be interconnected with SIMOTION D410 DP (connector
● The programming device / PC must be interconnected with SIMOTION D410 PN (connector
● You need a CF adapter on the programming device / PC to write to the Compact Flash
3.2

Inserting the Compact Flash card

Characteristics of the CF card
The CF card is mandatory for operation of SIMOTION D410. The SIMOTION Kernel and the
drive control software (SINAMICS firmware) are installed on the CF card.
SIMOTION D410
Commissioning Manual, 04/2014
cable.
Information pertaining to cable lengths for PROFIBUS DP is available in the
SIMOTION D410 Manual.
twisted pair cable.
For information on communication via PROFINET, refer to section Configuring PROFINET
(only for D410 PN) (Page 67).
X21) for online communication on PROFIBUS DP.
X200 and 201) for online communication on PROFINET.
Card (for example, a SIMOTION firmware update).