A detailed comparison of "local" and "global" measuring inputs as well as an overview of which
modules support local or global measuring inputs can be found in Chapter Configuring drive-
related I/Os (without symbolic assignment) (Page 215) in the appendix.
Procedure
If a global measuring input is selected, it must be assigned a hardware input.
To do this, open the assignment dialog box via
Note
Only those I/Os are displayed that have the appropriate measuring input functionality (MI_xx
[channel name, terminal number]). If no suitable I/Os are displayed, you must first configure
the I/Os (I/O must be configured as "measuring input")
Figure 5-32
Detailed information on the configuration of the TO measuring input can be found in the
SIMOTION Output Cams and Measuring Inputs Function Manual.
5.11.2

Configuring local measuring inputs

Local measuring inputs are drive-related measuring inputs. The configuration is performed via
drive parameters.
For further details, see:
● Configuring drive-related I/Os (without symbolic assignment) (Page 215) in the Appendix
SIMOTION D410
Commissioning Manual, 04/2014
Configuring a global measuring input for the D410
SIMOTION Output Cams and Measuring Inputs Function Manual
5.11 Configuring technology objects and I/O variables
and select a free (i.e. not yet used) I/O.
Commissioning (software)
135