A potential fault description could be as follows:
The SIMOTION D410 does not power up, the RDY LED flashes red at 0.5 Hz and the RUN/
STOP LED lights up red, or all the LEDs remain off.
In this case, replace the boot loader version with the current version.
Use the "Options > Write boot sector..." function to write the boot loader version in SIMOTION
SCOUT to the CF card.
Note
You require PG/PC administrator rights to write to the boot sector. If you do not have
administrator rights on your PG/PC, an administrator can enter an administrator login for you
to use this function under "Options" > "Settings" > "Rights."
Detailed information on the CF card, boot loader version, SIMOTION D410 hardware, and
SIMOTION firmware version compatibility relationships can be found in the software
compatibility list. You can find this list both in the documentation that comes with the
SIMOTION SCOUT DVD under \1_Important\German\Kompatibilitaet\... and on the Internet
under the following Internet address
18857317).
NOTICE
Different boot loaders
Note that CF cards for SIMOTION D410-2 and D4x5-2 may have a different boot loader!