2008 BODY & ACCESSORIES On-Board Diagnostic (Power Liftgate (PLG) System) - Mazda CX-9
DIAGNOSTIC PROCEDURE
DTC B267A - DIAGNOSTIC PROCEDURE
STEP
INSPECT WIRING HARNESS BETWEEN
PLG CONTROL UNIT AND LIFTGATE
LATCH AND LOCK ACTUATOR
Disconnect the PLG control module
connector.
1
Disconnect the liftgate latch and lock
actuator connector.
Inspect the wiring harness between PLG
control module terminal 3H and liftgate
latch and lock actuator terminal B for an
open circuit/short circuit to ground
system.
2008 Mazda CX-9 Grand Touring
INSPECTION
ACTION
Yes Go to the next step.
Repair or replace the wiring harness.
No
Go to Step 3.