Magnetic Compass Troubleshooting - Piper PA-24 Comanche Service Manual

Hide thumbs Also See for PA-24 Comanche:
Table of Contents

Advertisement

PIPER COMANCHE SERVICE MANUAL
1143. Gennal. The mqnetic compass installed in the Comanche
i~
a self-contained instrUment and
is
mounted above the Instrument
~.nel
on the windshield cmterstrip. This insrnammt hu an individual light
whiCh is connected to the instrUment lith tin, circuit. The comp. . cometion card is located in the card
holder mounted on the instrumenr panel.
1144. Troublellhooanl.
TABLE XI-VII. MAGNETIC COMPASS
Trouble
YUle
Remccty
Excessive card error.
Compus not properly
Compensate inSU\lment.
eompcnstated.
External m.,netic inter-
Locatt mqnetie inter-
frrmee.
ferenee and eliminate
if
possible.
I
Excessive card
I
Improper mounting on in-
Aliln instrument.
oscillarion.
strumenr panel.
Insufficient liquid.
Replaee instrUment.
!
Card slugglsn.
Weak card magnc:r.
Replace inserumenr.
I
Excessive pivot friction
Replace inserument,
I
I
or broken jeweL
I
I
Instrument tOO havily
Remove excess com pen-
I
eompensatcd.
sanon,
!
I
Liquid ieaKlie.
Loose bezel screws.
Replace InstrUment.
Broken cover gJass.
Replace instt\lmenr.
I
I
Defeetive scaling gaskets.
Replace instrument.
i
Replace instt\lment.
: Discolored luminous
Age.
;
:'T'larkin~s.
,
I
Dereenve light.
Burned our lamp or broken
Cheek lamp or connnuiev
;
circuit.
ofwinng.
INSTRUMENTS
ISSUED: B/18n2
3
811

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PA-24 Comanche and is the answer not in the manual?

Questions and answers

Table of Contents

Save PDF