Piper PA-24 Comanche Service Manual page 416

Hide thumbs Also See for PA-24 Comanche:
Table of Contents

Advertisement

PIPER COMANCHE SERVICE MANUAL
••••
FIGURE 78-7. FUEL AIR BLEED NOZZLE
NOTE
Do not exceed 60 inch-pounds torque on nozzles wh.en
aligninJ air
bleed
hole.
d.
Connect fuel line to nozzle.
CAUTION
SW't nozzles and line couplinp bY' hand to prevent the possibility of
c:ross-ehreadin"
e.
IftStall engine cowlinc.
78-37. IpitiOD Sysrem MaiDtnancc.
78·38. Inspection Of
Mapcm.
a.
Remove h.amess assembly cover from
mapetO
and inspect partS for moisture, broken leads or
other ciam.,c.
b.
Swinl lads out of outlets in distributOr block and remove two Krews sccurilll block in hOUSing.
Lift the block from mapcto.
c.
To properly inspect the breaker compartment and breaker points. it will be necessary to remove
the distributor t1ft1er by removing the two &ttachinJ screws
and
washers.
d.
Inspe« breaker poinrs for excessive wcu or burning. Desired contact surfaces will have
:l
dull gray
sandblasted or frosted appearance . .Minorin'qularitics or roulhncss of point surfaces arc not harmful.
POWER PLANT
1551;[0:
8/18/71
2
F12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents