CHAPTER 47    Automatic Provisioning
For enabling CRC, use the ini file parameter AUPDCheckIfIniChanged or CLI command, configure
system > automatic-update > crc-check regular. By default, CRC is disabled. For more information
on the parameter, see

Automatic Update Configuration Examples

This section provides a few examples on configuring the Automatic Update feature.

Automatic Update for Single Device

This simple example describes how to configure the Automatic Update feature for updating a single
device. In this example, the device queries the provisioning server for software, configuration and
Auxiliary files every 24 hours.
To set up Automatic Provisioning for single device (example):
1.
Set up an HTTP Web server (e.g., http://www.company.com) and place all the required
configuration files on this server.
2.
Configure the device with the IP address of the DNS server for resolving the domain name
(e.g., http://www.company.com) that is used in the URL of the provisioning server. You
configure this in the IP Interfaces table:
ini File:
[ InterfaceTable ]
FORMAT InterfaceTable_Index = InterfaceTable_ApplicationTypes,
InterfaceTable_InterfaceMode, InterfaceTable_IPAddress, InterfaceTable_
PrefixLength, InterfaceTable_Gateway, InterfaceTable_VlanID, InterfaceTable_
InterfaceName, InterfaceTable_PrimaryDNSServerIPAddress, InterfaceTable_
SecondaryDNSServerIPAddress, InterfaceTable_
UnderlyingDevice;InterfaceTable 0 = 6, 10, 10.15.7.95, 16, 10.15.0.1, 1, "Voice",
80.179.52.100, 0.0.0.0, "vlan 1";
[ \InterfaceTable ]
CLI:
# configure network
(config-network)# interface network-if 0
(network-if-0)# primary-dns 80.179.52.100
3.
Configure the device with the following Automatic Update settings:
a.
Automatic Update is done every 24 hours (1440 minutes):
b.
Automatic Update of software file (.cmp):
Automatic Update
ini File:
AutoUpdateFrequency = 1440
CLI:
# configure system
(config-system)# automatic update
(automatic-update)# update-frequency 1440
ini File: