CHAPTER 57    Reporting Information to External Party
Field
Remote
SSRC
Sender
[619]
Report Type
[303]
RTP IP
DiffServ
[624]
Session ID
[302]
Displays the remote (sender) RTP synchronization source (SSRC). The field is
an integer from 0 to 0XFFFFFFFF.
Note:
The field is included in the default CDR.
The field is applicable only to "CALL_END" and "MEDIA_END" CDR
Report Types.
The field is applicable only to SBC media and Gateway CDRs.
The default field title is "RemoteRTPssrc" for Gateway Syslog and
"RxRTPssrc" for SBC Syslog Media.
The maximum number of characters for Syslog tabular alignment is 14.
Displays the type of CDR report. The field is a string:
"CALL_START": The CDR is sent upon an INVITE message.
"CALL_CONNECT": The CDR is sent upon a 200 OK response.
"CALL_END": The CDR is sent upon a BYE message.
"DIALOG_START": The CDR is sent upon the start of a non-INVITE
session (only when enabled, using the EnableNonCallCdr parameter).
"DIALOG_END": The CDR is sent upon the end of a non-INVITE session
(only when enabled, using the EnableNonCallCdr parameter).
"DIALOG_CONNECT ": The CDR is sent upon establishment of a non-
INVITE session (only when enabled, using the EnableNonCallCdr
parameter).
"MEDIA_START": The CDR is sent upon 200 OK response or early media
"MEDIA_UPDATE": The CDR is sent upon a re-INVITE message
"MEDIA_END": The CDR sent is upon a BYE message
Note:
The field is included in the default CDR.
The field is applicable to all CDR Report Types.
The field is applicable to SBC media and signaling, and Gateway CDRs.
The default field title is "GWReportType" for Gateway Syslog and Local
Storage, "SBCReportType" for SBC Syslog and Local Storage, and
"MediaReportType" for SBC Syslog Media.
The maximum number of characters for Syslog tabular alignment is 15.
The field displays the RTP IP DiffServ. The valid value is an integer from 0 to
63.
Note:
The field is included in the default CDR.
The field is applicable to "CALL_END", "CALL_CONNECT", "MEDIA_
START", "MEDIA_UPDATE", "MEDIA_END" CDR Report Types.
The field is applicable only to SBC media and Gateway CDRs.
The default field title is "TxRTPIPDiffServ".
The maximum number of characters for Syslog tabular alignment is 15.
Displays the unique session ID. The field value is a string of up to 24